7.3Input and Output Signals
7.3.1Input and Output Signals
(1)RXD
Serial received data signal. If a framing error, overrun error, or parity error takes place, the relevant data will be printed as "?".
(2)DTR
Write the data or a command when this signal is Ready. If you write at Busy, the previous data will be ignored, resulting in an overrun error. The data can be written in the input buffer even during printing. Busy is also issued at
(3)TXD
If the remaining capacity of the input buffer comes to 128 bytes or less while receiving the data, DC3(13H) will be output as a data not receivable signal. If the remaining capacity comes to 256 bytes or more, DC1(11H) will be output to the host side as a data receivable signal.
When sending the status information, it is confirmed that DSR is a space prior to sending the data, if DTR/DSR control has been selected. If DTR/DSR control has not been selected, the data will be sent, ignoring the DSR signal.
(4)FG
Ground for the case
(5)GND
Common ground for the circuits
32 | CITIZEN |