9. Serial Interface
a) Synchronism b) Baud rate
Current Loop Type
c) Composition of one word :
Start bit | : 1 bit |
Data bit | : 7 or 8 bit (selected by user) |
Parity bit | : Odd, even or no parity (Selected user) |
Stop bit | : 1 bit or more |
d) Signal Polarity | : |
: *Mark = Logic “1” | |
| *Space = Logic “0” (+3V to +12V) |
Current Loop | : *Mark = Logic “1” (Current ON) |
Type | *Space = Logic “0” (Current OFF) |
TTL type | : *”H” level = Logic “1” Ref. to |
| *”L” level = Logic “0” |
e) Received Data :
f) Receiving Control (RD signal)
Current Loop : *Mark: (Current ON): Data Transfer possible *Space (Current OFF): Data Transfer not possible
g) Transmission Control (TD signal)
DC1 code (11H) “X” ON: | Data Receiving possible |
DC3 code (13H) “X” OFF: | Data Receiving not possible |
However, this is valid only for type B input buffer (7K).
CITIZEN | 23/48 |