9-3. Description of Input / Output Signals

9-3-1. Input / Output Signals

a) RD:

This is the serial signal for received data. When framing, overrun or parity errors occur, the data is converted into (7FH).

b) DTR:

Please write in data or commands when this signal is in a “ready” state. If written in when in

a BUSY state, an overrun error will occur and the data will be ignored. Data can be written into the input buffer even during printing. Further, a BUSY signal is generated when the power is turned on, while test printing, when ONLINE and during reset.

c) FAULT:

When there is a problem in the printer mechanism the FAULT signal will be issued, and all control circuits will be interrupted. To RESET this signal, first correct the cause of trouble in the printer mechanism. Then, by pressing the SEL switch or by inputting “0” (LOW LEVEL) at the RESET terminal, the FAULT can be cleared.

Causes of the FAULT signal are lack of paper and errors in the printer mechanism. Printer errors include such as, the print head stopping during print operation of failure of the print head to return to the home position.

d) RESET:

This signal resets the entire printer.

e) PE:

This signal is output when the paper roll is near the end.

f) TD (Valid only for type B):

When receiving data signals, and when the printer’s input buffer has less than 1K bytes remaining open, the DC3 code (13H) is issued, indicating that receipt of data is not possible. When the data in the input buffer is reduced to 2K bytes, the DC1 (11H) code is issued, which indicates that data receipt is possible.

g) FG:

Frame Ground

h) GND:

Common ground for all circuits.

CITIZEN

25/48

Image 25
Contents User’s Manual EMC LVDImportant Safety Instructions Contents Slide Switch Setting Serial interface specifications only Introduction Basic Specifications Specifications Citizen Block Diagram External Appearance and parts Description 12/48 13/48 Preparation IDP-3540/41 User’s Manual Ribbon Cassette Installation 16/48 17/48 Input Buffer Back-up Input Buffer Back-up FunctionParallel Interface Data FaultACK 21/48 22/48 Serial Interface DTR TTL25/48 26/48 27/48 8V Busy TD Mark = -8V +8V Ready Space = +8V Current on Ready External Output Function Selection IDP-3540/41 User’s Manual RS-422A type only Function Print Control Functions SO0EH FF0CHSI0FH CR0DH LF0AHRS1EH 37/48 38/48 39/48 40/48 DEFAULT=20 42/48 Initial Setting General Cautions MaintenanceCharacter Code Tables IDP-3540/41 User’s Manual Individual Country Character Codes External Dimensions IDP-3540/41 User’s Manual Model iDP3541