Citizen Systems iDP-562 user manual Start BIT, Data BIT + Parity BIT, Stop BIT

Page 19

iDP-562 User’s Manual

5.6DATA Construction

5.6.1 Serial Data format

1.Start BIT

2.DATA BIT (+ Parity BIT)

3.Stop BIT (1 ~ 2 BIT)

(1)START BIT

At 1 / 2 BIT after (a), signal level is checked out, (b). When signal level is MARK, continuous search for START BIT is made for the next bit.

(2)DATA BIT + PARITY BIT

DATA BIT and PARITY BIT are checked out every 1 / 2 BIT from the half point of START BIT, (b). Signal level of these points (MARK = 1, SPACE = 0) are read as input DATA.

The sequence of these BIT is BIT 0, BIT 1 ~ PARITY BIT from START BIT.

(3)STOP BIT

STOP BIT is 1 or 2 BIT and its signal level is MARK. If SPACE LEVEL is read at STOP BIT, FRAMING ERROR occurs.

CITIZEN

19

Image 19
Contents User’s Manual EMC LVDCITIZEN2 Citizen Important Safety InstructionsFCC Warning IDP-562 User’s Manual Contents Outline Basic Specifications Appearance and Parts Name Citizen Operation Citizen Citizen TTL Serial InterfaceCurrent Loop Space =OFF Data + LF + CR OFFData + CR OFF OFF Data + LF Data + CR + LFGND FaultCurrent TTL LoopCitizen Citizen 6CURRENT Loop Data BIT + Parity BIT Start BITStop BIT Citizen Citizen Data 3 Data 4 Data 5 Data 6 Data 7 Data Parallel InterfaceForeign character DSW-4 ACK, BUSY, SLCT, STB, Fault STB Twisted Pair GND Data ACK Busy Slct FaultPIN no LOW level Citizen Control Code CR0D ESC1B ESC81B Initial Setting Character Code Table Citizen SO Side Maintenance