Citizen Systems iDP-562 user manual ESC81B

Page 30

iDP-562 User’s Manual

6 Paging designation and page length designation

ESC(1B)

C(43)

n

Input ESC C (1B, 43) at the top of the line and next input n, which are integers. With this code, the length (number of line) per page can be set, and paging action is started, and the space of three lines are left at the both top and bottom of the page, n should be:

14 £ n £ 120

Otherwise, it comes to 66. The paging can be released by ESC O (1B, 4F).

7 Form Feed

FF(0C)

With this code, paper feed goes on. If there is data in the buffer when this code is input, the printer dose from feed after the printing. The top of from for the next page is made in accordance with the page length which was specified with ESC C n.

Top of position of the page is determined when power is turned on or when page length is specified with ESC C n.

8Canceling

CAN(18)

All the data input in one line prior to CAN are cleared entirely with this code.

9 Line Spacing Designation

ESC(1B)

1(31)

With this code, 2.75mm line spacing can be set for graphic print.

10 Standard Line Spacing Designation

ESC81B)

2(32)

With this code, 5.5mm line spacing can be set.

11 Reverse Characters Command

DC4(14)

DATA

CR(0D)

This code is used to input reverse characters command. If DC4 code is detected again on the same line, this command will be released.

It is possible to input DC4 code repeatedly on one line, completing one-line printing.

CITIZEN

30

Image 30
Contents User’s Manual LVD EMCCITIZEN2 Important Safety Instructions CitizenFCC Warning IDP-562 User’s Manual Contents Outline Basic Specifications Appearance and Parts Name Citizen Operation Citizen Citizen Space = Serial InterfaceCurrent Loop TTLOFF Data + LF Data + CR + LF OFFData + CR OFF OFF Data + LF + CRLoop FaultCurrent TTL GNDCitizen Citizen 6CURRENT Loop Start BIT Data BIT + Parity BITStop BIT Citizen Citizen Parallel Interface Data 3 Data 4 Data 5 Data 6 Data 7 DataForeign character DSW-4 STB Twisted Pair GND Data ACK Busy Slct Fault ACK, BUSY, SLCT, STB, FaultPIN no LOW level Citizen Control Code CR0D ESC1B ESC81B Initial Setting Character Code Table Citizen SO Side Maintenance