Citizen Systems iDP-562 user manual Foreign character DSW-4

Page 23

iDP-562 User’s Manual

6.2 Setting the Dip Switch

IDP562CNL / CN has Dip Switch with which you can select the followings to meet your computer’s function. Selection of “CR” and “LF” code function.

Please refer to the table below.

 

DSW-1

 

DSW-2

 

DSW-3

 

CR and LF code

When CR code comes

 

 

 

are valid function.

immediately after full

When the buffer is blank.

*OFF

CR code is selected

buffer printing

 

 

 

by the DSW-2

 

 

 

 

 

 

 

 

 

 

 

and 3.

*OFF

CR code is void

*OFF

CR code is valid

 

 

ON

CR code is valid

ON

CR code is void

 

 

 

 

 

 

 

CR code is ignored

When LF code comes

 

 

 

 

 

 

 

LF code is valid.

immediately after full

When the buffer is blank.

ON

LF code is selected

buffer printing

 

 

 

by the DSW-2

 

 

 

 

 

 

 

 

 

 

 

and 3.

*OFF

LF code is void

*OFF

LF code is valid

 

 

 

 

 

 

 

 

ON

LF code is valid

ON

LF code is void

 

 

 

 

 

 

It is recommended to set the DIP switches in accordance with your host’s output DATA format.

DATA Form

 

DSW-1

DSW-2

DSW-3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DATA + CR

 

OFF

OFF

 

OFF

 

 

 

 

DATA + LF

 

 

 

 

 

 

 

 

 

 

 

DATA + CR + LF

 

ON

OFF

 

OFF

 

 

 

 

DATA + LF + CR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USA

 

GERMANY

FRANCE

UK

Foreign character

 

 

 

 

 

 

 

 

DSW-4

 

*OFF

 

 

OFF

ON

ON

Selection

 

 

 

 

 

 

 

 

 

 

 

DSW-5

 

*OFF

 

 

ON

OFF

ON

 

 

 

 

DSW-6

 

 

 

 

 

 

 

 

 

 

 

¯

 

 

 

 

 

 

Not for use

 

 

DSW-10

 

 

 

 

 

 

 

 

 

 

 

NOTE: *Marks are a “Factory Setting”

 

 

 

 

 

 

 

CITIZEN

23

Image 23
Contents User’s Manual CITIZEN2 LVDEMC Citizen Important Safety InstructionsFCC Warning IDP-562 User’s Manual Contents Outline Basic Specifications Appearance and Parts Name Citizen Operation Citizen Citizen TTL Serial InterfaceCurrent Loop Space =OFF Data + LF + CR OFFData + CR OFF OFF Data + LF Data + CR + LFGND FaultCurrent TTL LoopCitizen Citizen 6CURRENT Loop Stop BIT Start BITData BIT + Parity BIT Citizen Citizen Data 3 Data 4 Data 5 Data 6 Data 7 Data Parallel InterfaceForeign character DSW-4 PIN no STB Twisted Pair GND Data ACK Busy Slct FaultACK, BUSY, SLCT, STB, Fault LOW level Citizen Control Code CR0D ESC1B ESC81B Initial Setting Character Code Table Citizen SO Side Maintenance