Carrier D2-3466-2 instruction manual Monitor Mode

Page 13

CHAPTER 3

Using the Keypad/Display to Program, Monitor, and Control the Drive

If you are unfamiliar with the detailed operation of the keypad/display, refer to chapter 3 of the LiquiFlo Software Start-Up and Reference Manual (D2-3410).

 

Display

Drive Status

Keypad

 

 

LEDs

 

 

 

P.---

AUTO

Forward

 

 

 

Monitor Mode

SPEED

RUNNING

MAN

Reverse

VOLTS

REMOTE

 

 

LEDs

AMPS

JOG

 

RUN

Hz

AUTO

PROGRAM

 

Kw

FORWARD

 

JOG

Password LED

TORQUE

REVERSE

 

 

Password

PROGRAM

ENTER

 

STOP

START

RELIANCE

 

RESET

 

 

 

 

 

ELECTRIC

Stop / Reset Key

Start Key

Figure 3.1 – Keypad/Display

ATTENTION: When switching from auto to manual, or manual to auto, the drive will ramp to the reference level provided by the new source at

!the rate specified in P.001 (Accel Time 1), P.002 (Decel Time 1), P.017 (Accel Time 2), or P.018 (Decel Time 2). Be aware that an abrupt speed change may occur depending upon the new reference level and the rate specified in these parameters. Failure to observe this precaution could result in bodily injury.

Using the Keypad/Display to Program, Monitor, and Control the Drive

3-1

Image 13
Contents Carrier VFD Quick Reference Page Page Page Page Page Contents Carrier VFD Quick Reference Getting Assistance from Reliance Electric Required PublicationsCarrier VFD Quick Reference Replace with 2.fm 11 X 17 Z-fold Carrier VFD Quick Reference Monitor Mode Carrier VFD Quick Reference For Carrier Drives Carrier VFD Quick Reference Record the following nameplate information Record the following job informationCarrier VFD Quick Reference Verifying That DC Bus Capacitors Are Discharged Test Equipment Needed To TroubleshootPOS NEG TP1 TP2 Initial DC Bus Checking the Power Modules and Motor with Input Power Off Igbt Alarm Codes Troubleshooting the Drive Using Error CodesFault Codes Error LogAlarm Code Description Alarm Cause Corrective Action Identifying Alarm Codes and RecoveringFault Code Description Fault Cause Corrective Action Identifying Fault Codes and RecoveringIPL OPL Asymmetrical Bus When Input Ground Fault ExcessiveSlow Ramp Rate of DC Bus DC Carrier VFD Quick Reference Troubleshooting the Drive Code Fault Description Fault Cause Corrective Action Identifying Fatal Fault Codes and RecoveringResetting a Checksum CHS Fault Indentifying PMC Board Fault Codes and RecoveringStatus of LEDs Fault Description Corrective Action Model Amps Code Number Technical Writing Internal Use DIFPage Page Publication D2-3466-2 May 2005 -- Supercedes D2-3466-1 June