Terminal Setup
Printer Type
This scrolling list selects the attached printer type. The default value is none, indicating that no printer is attached.
Terminal Setup Using Twin Client Menus
The Twin Client terminal software provides an internal menu system for configuring certain parameters on the terminal and for switching between Server and Telnet modes of operation.
To access this menu system for the BHT 7500 terminal, press uppercase C at the startup screen as shown in the following figure.
Twin Client
©
Keypress to Continue
The following screen appears.
Edit Menu Options
Edit Mobile Unit IP
Edit Server/Host IPs
Edit License Key
Run Site Survey
Switch Client Modes
Run Client Emulator
Exit to OS
Use the
Edit Mobile Unit IP
The IP list contains the terminal IP address, the Subnet Mask and the Router IP address. Enter the appropriate address and select F3 to save and/or F7 to Quit.
IP 206.232.71.38
SN 255.255.255.0
RT 206.232.71.1
<F3> Save <F7> Quit
Edit Server/Host IPs
If the host IP address(es) were not
Supported Equipment Manual • March, 2006 |