Graco 15V534 important safety instructions Install the Air Flow Switch, AFS#2

Page 5

Install the Air Flow Switch

NOTE: The GFB Interface Module Kit does not include an air flow switch (AFS). The AFS is supplied with the gun flush box kit. Install the AFS in the interface module as follows.

1.Each gun flush box kit includes one air flow switch (AFS). The GFB interface module can accommo- date 1 or 2 air flow switches. Install the switch(es) in the right side of the enclosure. See FIG. 3.

1 AFS is part of gun flush box kit; not included with GFB Interface Kit.

AFS#1 1

AFS#2

1

TI14281a

FIG. 3. Install Air Flow Switch (two shown)

Installation

2.Connect the wires from AFS#1 to the right side of the terminal strip (12) pins 1 (+) & 2 (-), as indicated by the label (21). See FIG. 4 and Table 1.

12 21

TI14279a

FIG. 4. Connect Air Flow Switch to Terminal Strip

3.If using a second gun flush box, connect the wires from AFS#2 to the right side of the terminal strip (12) pins 3 (+) & 4 (-), as indicated by the label (21). See FIG. 4 and Table 1.

313212A

5

Image 5
Contents 15V534 Gun Flush Box Interface Kit Overview ContentsRelated Manuals Mount the Enclosure InstallationLocation Connect Cable to Terminal Strip Install the CableAFS#2 Install the Air Flow SwitchInstall Pressure Switch two shown Install the Pressure SwitchInstall Solenoid two shown Install the SolenoidRoboMix Control Board J1 Connections Connect the Cable to the RoboMix Control BoardConnect Air Supply to Module Connect the Gun Flush Box Replace the CoverGround the Enclosure Installation 12 Ref PartsConnect a Booth Control to the RoboMix Technical Data DimensionsGraco Information Graco Standard Warranty