Graco 15V534 Install the Pressure Switch, Install Pressure Switch two shown

Page 6

Installation

Install the Pressure Switch

NOTE: The GFB Interface Module Kit does not include a pressure switch (PS). The pressure switch is supplied with the gun flush box kit. Install the pressure switch in the interface module as follows.

1.Each gun flush box kit includes one pressure switch (PS). The GFB interface module can accommodate 1 or 2 pressure switches. Install the switch(es) in the left side of the enclosure. See FIG. 5.

1 Pressure switch is part of gun flush box kit; not included with GFB Interface Kit.

1PS#1

PS#2

1

TI14282a

FIG. 5. Install Pressure Switch (two shown)

2.Connect the wires from PS#1 to the right side of the terminal strip (12) pins 5 (+) & 6 (-), as indicated by the label (21). See FIG. 6 and Table 1.

12 21

TI14279a

FIG. 6. Connect Pressure Switch to Terminal Strip

3.If using a second gun flush box, connect the wires from PS#2 to the right side of the terminal strip (12) pins 7 (+) & 8 (-), as indicated by the label (21). See FIG. 6 and Table 1.

6

313212A

Image 6
Contents 15V534 Gun Flush Box Interface Kit Contents Related ManualsOverview Installation Location Mount the Enclosure Install the Cable Connect Cable to Terminal StripInstall the Air Flow Switch AFS#2Install the Pressure Switch Install Pressure Switch two shownInstall the Solenoid Install Solenoid two shownConnect the Cable to the RoboMix Control Board RoboMix Control Board J1 ConnectionsConnect the Gun Flush Box Replace the Cover Ground the EnclosureConnect Air Supply to Module Installation Parts 12 RefConnect a Booth Control to the RoboMix Dimensions Technical DataGraco Standard Warranty Graco Information