Installation

Connect the Cable to the RoboMix Control Board

NOTICE

To avoid damaging circuit board when servicing, wear grounding strap on wrist and ground appropriately.

1.See the ProMix 2KS Repair-Parts manual. Open the RoboMix to access the control board.

2.Connect the 10 position connector (24) to J1 on the control board. See FIG. 9.

J1 Pins 1-4, 7-10

(10 position

Connector 24)

FIG. 9: RoboMix Control Board J1 Connections

3.Connect the 6 position connector (25) to J8 on the control board. See FIG. 10

J8 Pins 1-4

(6 position Connector 25)

FIG. 10: RoboMix Control Board J8 Connections

8

313212A

Image 8
Contents 15V534 Gun Flush Box Interface Kit Overview ContentsRelated Manuals Mount the Enclosure InstallationLocation Install the Cable Connect Cable to Terminal Strip Install the Air Flow Switch AFS#2Install the Pressure Switch Install Pressure Switch two shownInstall the Solenoid Install Solenoid two shownConnect the Cable to the RoboMix Control Board RoboMix Control Board J1 ConnectionsConnect Air Supply to Module Connect the Gun Flush Box Replace the CoverGround the Enclosure Installation Parts 12 RefConnect a Booth Control to the RoboMix Dimensions Technical DataGraco Standard Warranty Graco Information