Graco 15V534 Connect the Gun Flush Box Replace the Cover, Ground the Enclosure

Page 9

Installation

Connect the Gun Flush Box

Replace the Cover

NOTE: Use 5/32 in. (4 mm) OD tubing to connect the gun flush box air ports to the interface module air ports, as follows. See FIG. 12.

1.From the P port to the air supply.

2.From the A port to the pressure switch air input.

3.From the C port to the gun flush box solenoid out- put.

4.From the S port to the atomizing air safety shutoff valve pilot port. See the gun flush box manual for details on the safety shutoff valve.

5.From the AFS to the atomizing air safety shutoff valve IN port. See the gun flush box manual for details on the safety shutoff valve.

Reinstall the cover on the enclosure and secure with the four captive screws.

Ground the Enclosure

Connect a ground wire (Y) from the enclosure’s ground screw (6) to a true earth ground. See FIG. 11.

Y

6

TI14277a

Connect Air Supply to Module

FIG. 11. Ground the Enclosure

Connect a 1/4 in. (6 mm) OD tube between a clean, dry air supply (filtered to 10 microns) and the module air inlet fitting (13). See Parts on page 11.

GUN FLUSH BOX

P

A

INTERFACE MODULE

P

A

C

S

C

AFS

 

S

AIR SAFETY

 

 

 

SHUTOFF VALVE

 

C

P

 

 

 

IN

TI14278a

 

 

TI13110b

 

FIG. 12: Gun Flush Box to Interface Module Air Connections

313212A

9

Image 9
Contents 15V534 Gun Flush Box Interface Kit Contents Related ManualsOverview Installation LocationMount the Enclosure Connect Cable to Terminal Strip Install the CableAFS#2 Install the Air Flow SwitchInstall Pressure Switch two shown Install the Pressure SwitchInstall Solenoid two shown Install the SolenoidRoboMix Control Board J1 Connections Connect the Cable to the RoboMix Control BoardConnect the Gun Flush Box Replace the Cover Ground the EnclosureConnect Air Supply to Module Installation 12 Ref PartsConnect a Booth Control to the RoboMix Technical Data DimensionsGraco Information Graco Standard Warranty