Connect a Booth Control to the RoboMix (to operate as a manual system)

Connect a Booth Control to the RoboMix (to operate as a manual system)

To use the RoboMix as a manual system, order the 15V350 Booth Control Kit and connect as follows. The kit includes a booth control module, wall bracket, and 50 ft (15.25 m) cable.

NOTICE

To avoid damaging circuit board when servicing, wear grounding strap on wrist and ground appropriately.

Cable Path

TI12511a

Booth Control

1.See FIG. 13. Mount the booth control in a convenient location near the RoboMix. Bring the cable to the RoboMix and thread it through the cable path at the back.

2.See the ProMix 2KS Repair-Parts manual. Open the RoboMix to access the control board.

3.Connect the cable to J7 on the control board. Close up the RoboMix and return to operation.

J7. Plug In for

Booth Control

Cable

Booth Control Cable

RoboMix Control Board

RoboMix

TI15110a

FIG. 13. Connect a Booth Control to the RoboMix

12

313212A

Image 12
Contents 15V534 Gun Flush Box Interface Kit Contents Related ManualsOverview Installation LocationMount the Enclosure Install the Cable Connect Cable to Terminal StripInstall the Air Flow Switch AFS#2Install the Pressure Switch Install Pressure Switch two shownInstall the Solenoid Install Solenoid two shownConnect the Cable to the RoboMix Control Board RoboMix Control Board J1 ConnectionsConnect the Gun Flush Box Replace the Cover Ground the EnclosureConnect Air Supply to Module Installation Parts 12 RefConnect a Booth Control to the RoboMix Dimensions Technical DataGraco Standard Warranty Graco Information