Minuteman UPS SentryII UPS user manual Novell Netware Client, User Management on

Page 33

Server Address

The SentryII Server’s IP address.

Server Port

The API port number of the SentryII Server. (See Server Settings on page 13)

Username

The default is admin. This setting must coincide with the defined SentryII users list. (See

 

 

User Management on page 13)

Password

The default is admin. This setting must coincide with the defined SentryII passwords list.

 

 

(See User Management on page 13)

On Battery Shutdown

The amount of time in seconds, after the event occurs, before the Remote Client will be

 

 

shutdown. If the event is removed before the delay time is reached, the action will be

 

 

cancelled. (See UPS and/or Operating System Shutdown on page 20)

Low Battery Shutdown

The amount of time in seconds, after the event occurs, before the Remote Client will be

 

 

shutdown. (See UPS and/or Operating System Shutdown on page 20)

NOTE: All Remote clients need to be configured to shutdown before the SentryII Server.

Starting SentryII Services

If, at the end of the installation, you selected to start SentryII, then SentryII should be running. If not, to start SentryII, perform the following steps:

Windows 95/98/ME

1.Click the Windows Start button and select Programs / SentryII / SIIRemote.

2.SentryII Remote is a hidden service and may only be seen by pressing Ctrl-Alt-Delete.

Windows NT/2000/XP

1.Start the Windows Services application.

2.From the Windows Start Menu, select the Settings menu, and then select the Control Panel menu.

3.Select the Administrative Tools folder, and then select the Services application.

4.Locate the SentryII Remote service in the services list.

5.Right click SentryII Remote and select Start from the popup menu.

Novell Netware Client

Installation

Step 1. The SentryII Remote must be installed from a Windows client computer. the SentryII Server installation. (see Novell Netware Install Procedure

This should be done in exactly the same manner as page 7)

- 33 -

Image 33
Contents Minuteman Table of Contents Installation Starting SentryII Services Installing the UPS Interface Cable InstallationIntroduction System RequirementsFrom the Windows Quick Launch Toolbar Starting SentryII ServicesUninstall Procedure Connect to ServiceNovell Netware Connecting to UPS UPS connected successfully Connect to Service Unix HP-UX Connect to Service User Management ConfigurationServer Settings UPS Configuration Event Configuration Event ActionPaging Page Snmp Trap LoggingEmail Notification BroadcastingUPS and/or Operating System Shutdown Run a System Command Page Monitoring MeterIdentification Battery InputOutput View Graphic AlarmPage Scheduling UPS Control OptionsControl ScheduleData & Event Logging Log ConfigurationPage View Data Log View Event Log Sentryii RemoteWindows Client InstallationUser Management on Novell Netware ClientUser Management on Unix Client User Management on HP-UX