Minuteman UPS ED6000T, ED6200T user manual Installation Placement, Storage Instruction

Page 8

3.2.Installation Placement

This UPS system is intended to be install in a temperature controlled environment that is free of conductive contaminants. Select a location, which will provide good air circulation for the UPS at all times. Keep at least 12 inches (30cm) clearance from the rear panel of the UPS to the wall. Avoid locations near heating devices, water or excessive humidity, or where the UPS is exposed to direct sunlight. Route power cords so they cannot be walked on or damaged.

ENVIRONMENTAL

Operating Temp (max)

0 to 40ºC (+32 to +104ºF) <2000m (<+6700 ft)

0 to 35ºC (+32 to +95ºF) at 3000m (+10,000 ft)

 

 

 

Storage Temp

-15 to +45ºC (+5 to +113ºF)

Operating/Storage Humidity

30 - 90% Non-Condensing

Storage Elevation

0 to 15,000m (0 to +50,000 ft)

3.3.Storage Instruction

For extended storage with moderate climates, the batteries should be charged for 12-hours every 3 months. Repeat this procedure every 2 months under high temperature environments.

3.4.Installation of the Caster Covers

3.4.1Lock the casters so that the unit will not move.

3.4.2Step 1: There are two A1 cover plates, one for each side of the unit. Insert the A1 cover plates into the slots and slide towards the rear of the unit.

3.4.3Step 2: There are two A2 cover plates, one for the front of the unit and one for the rear of the unit. Insert the A2 cover plates into the slots and push downwards toward the floor.

3.4.4Step 3: There are four retaining screws S1. Install the S1 retaining screws into the A2 cover plates.

3.4.5Step 4: There is one A3 cover plate. Insert the A3 cover plate into the holes on the A2 cover plate on the front of the unit and press firmly.

12

13

Image 8
Contents ED6000T & ED6200T Parallel RedundantTable of Contents Important Safety Instruction An Important NoticeLife Support Policy FCC NoticeProduct Introduction EPO Controls and Indicators Installation and Operation Qualified Service Personnel onlyRear Panel UnpackingStorage Instruction Installation PlacementInstallation of the Caster Covers Wiring the Input and Output Connections AWGPage Operation and Setup Instructions Page It shows the UPS is providing power to the load It shows the Internal Temperature of the UPS System Page LED LCD Power Monitoring Software EPO Emergency Power Off PortCommunication Port, EPO Port and Option Cards RS232 Communication PortReplacing the Batteries Troubleshooting GuideService Personnel only Battery Replacement Procedure Page Regulatory Compliance SpecificationsPhysical Obtaining Service Limited Product WarrantyDeclaration of Conformity

ED6200T, ED6000T specifications

The Minuteman UPS ED6000T and ED6200T are robust uninterruptible power supply (UPS) systems designed to offer reliable protection for sensitive electronic equipment. These units stand out in the market for their enhanced features, advanced technologies, and exceptional performance.

The core design of the ED6000T and ED6200T integrates a pure sine wave output, ensuring compatibility with all types of devices, including sensitive electronics and critical infrastructure. This feature minimizes electrical distortion, providing protection against damage from power fluctuations. They deliver up to 6000VA and 6200VA of power respectively, making them suitable for small to medium-sized data centers, telecommunications equipment, and critical servers.

One key characteristic of these models is their comprehensive LCD display that provides real-time monitoring of UPS status, battery charge level, load percentage, and other essential diagnostics. This user-friendly interface makes it convenient for users to assess performance at a glance and manage their power protection strategies effectively.

Both models employ advanced battery management technologies, including Smart Battery Management that extends battery life through optimized charging cycles. This is crucial for maintaining reliability, especially in environments where power outages can be frequent and disruptive. The UPS units also feature an automatic voltage regulation (AVR) system that corrects minor voltage fluctuations, maintaining consistent output without switching to battery mode.

Additionally, the ED6000T and ED6200T incorporate the Minuteman Green Power UPS™ technology, designed to minimize energy consumption and reduce heat output, thus contributing to lower operational costs and environmental sustainability. With an energy-efficient design, they are not only financially beneficial but also eco-friendly.

Connectivity options are another highlight, as both models feature multiple outlets, including surge-protected and battery backup outlets, ensuring plenty of connections for various devices. They are equipped with USB and serial communication ports that allow for seamless integration with monitoring and management software, thereby enhancing their functionality in networked environments.

In conclusion, the Minuteman UPS ED6000T and ED6200T are powerful solutions for businesses seeking reliable power protection. With their pure sine wave output, advanced battery management, user-friendly interfaces, and energy-efficient designs, they represent a solid investment for safeguarding critical electronics against power interruptions.