TM
CODES (HEX/CONTROL) : 19 / <EM>
FUNCTION : Immediate drive command for peripheral unit 2
APPLICATION LIMIT : Peripheral units 1 and 2 cannot be driven simultaneously.
DETAIL DESCRIPTION : Drives peripheral unit 2. Pulse width is fixed at 200ms with a fixed delay time of 200ms. Same as <SUB>.
CODES (HEX/CONTROL) : 1A / <SUB>
FUNCTION : Immediate drive command for peripheral unit 2
APPLICATION LIMIT : Peripheral units 1 and 2 cannot be driven simultaneously.
DETAIL DESCRIPTION : Drives peripheral unit 2. Pulse width is fixed at 200ms with a fixed delay time of 200ms.
APP. A STAR …
CODES (HEX/CONTROL) : 1B 07 n1 n2 / <ESC> <BEL> n1 n2
FUNCTION : Adjust drive pulse width for peripheral unit 1
DEFINITION RANGE : 1 ≤ n1 ≤ 127, 1 ≤ n2 ≤ 127
APPLICATION LIMIT : Adjustment is not necessary for standard cash drawers in the U.S.A. market.
DETAIL DESCRIPTION : Adjusts drive pulse width for peripheral device #1 requiring other than standard 200 ms pulse time and recovery time.
Energizing time = 10 x n1 ms Recovery time = 10 x n2 ms Executed by <BEL> or <FS> code.
Printing and paper feed are prohibited throughout the energizing and recovery time.
CODES (HEX/CONTROL) : 1B 25 00 / <ESC> “%” <0>
FUNCTION : Disable download character set
DETAIL DESCRIPTION : Disable the selected download character set and selects the
A - 6