0$*0$
Notes:
1.This table applies to CB1 systems only. Do NOT use for CB2 systems.
2.Calculations assume continuous operation at maximum designed load.
3.Margin of safety used is 10%.
4.Determine the number of Desired Continuous Operating Hours you would like to operate before recharging. (Column 1)
5.Determine the Battery Output Voltage of the battery you would like to use. (Column
6.Read the cell value in the table for the Amp Hours required. Use this number when choosing a battery (or set of batteries).
7.If you required more than 8 hours- use multiples of a lesser number of hours.
Examples:
If you want 5 hours of continuous operation with a 14.4VDC battery set: Locate row 5 in Column 1 of the table above, read across the row to the 14.4VDC Column, you will find that you will need a battery (or set of batteries) with a total power rating of about 17 Amp Hours.
If you want 10 hours of continuous operation with this same battery set (at 14.4VDC), would need a total power rating of about 34 Amp Hours (2 x 17 from the above example).
For Batteries Rated in Watt Hours:
If the vendor rates the batteries in Watt Hours, then simply multiply the number of desired hours of use by 45 to get total Watt Hours rating requirement.
If you want to run the CB1 for up to 4 hours: 4 hours x 45 Watts = 180 Watt Hours is required for the selected battery set.
6ORW6HULHV8VHUV0DQXDO |