Quantum Scalar 50 Tape Drive Installation Instructions
Document
September 2007
6To change a SCSI ID, enter the ID number in the field next to the device and click Apply.
7From the Operations page, click on the Drives tab. The Drives page displays (see figure 15):
Figure 15 Drives Page
Drive operations
8Enter the new tape drive number
9Select shutdown and click Apply. The tape drive powers down.
10Enter the new tape drive number
11Select Power on and click Apply.
The tape drive powers on. The tape drive installation is complete.
Note: The firmware revision on the new tape drive(s) must match the firmware revision on the currently installed tape drives (of the same tape drive type). If the new tape drive has a different revision, you must download the appropriate tape drive firmware from Quantum and update the drive. All tape drives in the library must contain the same firmware revision. You can view the tape drive firmware revision on the OCP under Drive Operations.
Completing the Native Fibre Channel Installation
After native Fibre Channel tape drives are installed, additional information must be gathered to complete the installation and verify connectivity. Competing the native Fibre Channel tape drive installation consists of the following steps:
14 | Completing the Native Fibre Channel Installation |