The procedures in this section will help keep your Rimage 360i in optimum operating condition.

General Cleaning

Tip: To keep your Rimage 360i clean, keep it in a dust free environment.

Tip: Use only Rimage inkjet print cartridges and, for best results, follow the guidelines below:

Keep print cartridges sealed in the original package until they are needed.

Store print cartridges at room temperature (60 - 78 degrees F or 15.6 to 26.6 degrees C)

Store print cartridges in an upright position - not on their sides or upside down.

Do not remove the protective tape from a new print cartridge until just before you install it. Once you remove the tape, do not reapply it.

After you have removed the protective tape, avoid touching the contacts and nozzles.

Print at least once a month to keep the print cartridges in good working order.

Cleaning the exterior

If your Rimage 360i becomes dusty:

1.Power off the Rimage 360i.

2.Wipe the exterior with a damp, lint-free cloth.

Cleaning the ink cartridge nozzles

This functionality allows you to clean or open the ink cartridge nozzles. The nozzles may become clogged from dried ink causing poor print because one or more nozzles are not delivering the appropriate quantity of ink.

1.Navigate to Printing Preferences (refer to page 9).

2.On the Service tab, select the Service ToolBox button.

3.Select the Clean Cartridges button. The Cleaning Cartridges window opens.

4.To clean the ink cartridge nozzles using the least amount of ink, select Light. The status field at the bottom of the Cleaning Cartridges window displays a message when the cleaning is complete.

Note: Print a test disc after cleaning the ink cartridge nozzles. If the print quality is poor, repeat this process and, in step 4, select Medium or Heavy to clean the ink cartridge nozzles.

5.To close the Cleaning Cartridges window, select OK.

6.To close the Rimage Service ToolBox window, select OK.

7.To close the Disc Color 360i Properties window, select OK.

110808_C

15

Image 21
Contents Rimage 360i User Guide Page Corporate Headquarters European HeadquartersCD and DVD Recording Software Disclaimer North America RimageEurope South AmericaContents ContentsIntroduction Maintain the RimageRimage Requirements IntroductionSoftware requirements Operating System requirementsLabel design requirements Identify the parts of the Rimage Front ViewIdentify the parts of the Rimage Pause button Rimage 360i ButtonsImage Rimage 360i Project Status Indicator PSIName FunctionalityFilter Cover Rear Cover Power Switch Power Cord Port USB Port Rear viewPausing the Rimage Powering on the RimageOperate the Rimage Operate the RimageLoading the discs 1. Open the input door3. Close the input door Accessing Printer Preferences through CD Designer Accessing Printing Preferences through Windows Start menuSelect your printing preferences Navigating to Printing PreferencesSetting the print quality Adding, editing, or deleting a watermarkc. Select OK. The Digital Photography Options window closes Adjusting the ink volume used Setting up color options3. Turn Print in Grayscale on or off Printing on hub with a stacking ring Changing or enabling maskingTip The image below shows a disc with a stacking ring Standard AreaPrinting on hub without a stacking ring Aligning the ink cartridgesTip The image below shows a disc with no stacking ring Checking the ink levels Centering the image on the discCleaning the exterior General CleaningCleaning the ink cartridge nozzles Maintain the RimageReplacing the fan filter Replace Consumables7. Close the ink cartridge access door Replacing the ink cartridgesc. If the problem persists, replace the cartridge a. Remove the cartridge and reinsert itLearn More Rimage 360i SpecificationsSafety information Technical support and product updatesSafety precautions Learn MoreSafety testing Product name RimageModel RAS17 Rimage 360i Limited 1 Year Warranty