Rimage 360i manual Centering the image on the disc, Checking the ink levels, Rimage

Page 20
Centering the image on the disc

Checking the ink levelsRimage 360i

Centering the image on the disc

The Rimage 360i provides two ways to center the image on the disc. You can use the Auto Centering method or the Manual Centering method. The Auto Centering method is accurate to within +/- 0.5 mm. You can improve the centering position accuracy with the manual centering adjustment to better than +/- 0.2 mm. For optimal print quality, use this procedure to center the image on the disc.

Tip: Use the Center Image functionality only if the printed image is not centered on the disc. Image centering is set at the time of manufacture and usually does not need to be recalibrated in the field.

1.Navigate to Printing Preferences (refer to page 9).

2.At the Rimage 360i, open the front cover.

3.To open the printer tray, press the green (middle) button inside the front cover of the Rimage 360i. The printer tray opens.

4.On the Service tab, select the Service ToolBox button.

5.Select the Center Image button. The Centering Margins for Disc Color 360i dialog box displays.

6.Follow the directions in the dialog box to:

Auto center the image

Or

Manually center the image

7.When the image is centered, select OK to close the Centering Margins for Disc Color Printer 360i dialog box.

8.To close the Rimage Service ToolBox window, select OK.

9.To close the Disc Color 360i Properties window, select OK.

10.To close the printer tray, press the green (middle) button. The printer tray closes.

11.Close the front cover.

Tip: If you remove the ink cartridges and reinsert them, the system resets to show that the cartridges are full, regardless of the actual fill status.

Checking the ink levels

This functionality allows you to check the level of ink in the cartridges.

1.Navigate to Printing Preferences (refer to page 9).

2.On the Service tab, select the Service ToolBox button.

3.Select the Get Ink Level button. Ink level information displays in the Printer Status field.

4.To close the Rimage Service ToolBox window, select OK.

5.To close the Disc Color 360i Properties window, select OK.

14

110808_C

Image 20
Contents Rimage 360i User Guide Page CD and DVD Recording Software Disclaimer Corporate HeadquartersEuropean Headquarters Rimage North AmericaEurope South AmericaContents ContentsIntroduction Maintain the RimageRimage Introduction RequirementsSoftware requirements Operating System requirementsLabel design requirements Identify the parts of the Rimage Identify the parts of the RimageFront View Rimage 360i Buttons Pause buttonRimage 360i Project Status Indicator PSI ImageName FunctionalityRear view Filter Cover Rear Cover Power Switch Power Cord Port USB PortPowering on the Rimage Pausing the RimageOperate the Rimage Operate the Rimage3. Close the input door Loading the discs1. Open the input door Accessing Printing Preferences through Windows Start menu Accessing Printer Preferences through CD DesignerSelect your printing preferences Navigating to Printing Preferencesc. Select OK. The Digital Photography Options window closes Setting the print qualityAdding, editing, or deleting a watermark 3. Turn Print in Grayscale on or off Adjusting the ink volume usedSetting up color options Changing or enabling masking Printing on hub with a stacking ringTip The image below shows a disc with a stacking ring Standard AreaTip The image below shows a disc with no stacking ring Printing on hub without a stacking ringAligning the ink cartridges Centering the image on the disc Checking the ink levelsGeneral Cleaning Cleaning the exteriorCleaning the ink cartridge nozzles Maintain the RimageReplace Consumables Replacing the fan filterReplacing the ink cartridges 7. Close the ink cartridge access doorc. If the problem persists, replace the cartridge a. Remove the cartridge and reinsert itRimage 360i Specifications Learn MoreTechnical support and product updates Safety informationSafety precautions Learn MoreModel RAS17 Safety testingProduct name Rimage Rimage 360i Limited 1 Year Warranty