Teledex IP250DVoIP manual CUSTOM3 CUSTOM4 CUSTOM5 CUSTOM6 CUSTOM7 CUSTOM8 CUSTOM9

Page 31

APPENDICES

"CUSTOM_3" "CUSTOM_4" "CUSTOM_5" "CUSTOM_6" "CUSTOM_7" "CUSTOM_8" "CUSTOM_9"

Idle ::= "IDLE"

Active ::= "ON" "OFF"

Inactive ::= Idle "(" Timeval ")"

Active ::= Active "(" Timeval ")" Sequence ::= Active Active "," Sequence Repetition ::= "[" Sequence "]" Repeatval Repeat ::= "R"

Cycle ::= Sequence Repetition

Fullsequence ::= Cycle Cycle "," Fullsequence Cadence ::= Fullsequence Fullsequence "," Repeat

Fullsequence "," Inactive "," Repeat Toneref ::= "{" Tonename "}"

Toneseq ::= Toneref Toneref "" Toneseq Freqcomp ::= Freqval "@" Powerval

Freq ::= Freqcomp Freqcomp "+" Freqcomp Tone ::= Toneseq Freq "#" Cadence

EXAMPLE TONE CONFIGURATIONS

Example 1: A European Dial Tone

DIALTONE 425@-5#ON(1000),R

Example 2: A European Ringback Tone

RINGBACK 425@-10#ON(1000),OFF(5000),R

Example 3: Custom Tones

CUSTOM_1 950@-25#ON(330),OFF(30)

CUSTOM_2 1400@-25#ON(330),OFF(30)

CUSTOM_3 1800@-25#ON(330),OFF(30),IDLE(1000)

CUSTOM_4 {CUSTOM_1}{CUSTOM_2}{CUSTOM_3}

A Config File Example

Name Value

DIALTONE 450@-5#ON(1000),R

RINGBACK 450@-10#ON(1000),OFF(4000),R

NETWORK_BUSY 450@-10#ON(350),OFF(350),R

BUSY 450@-10#ON(350),OFF(350),R

Teledex IP250D User’s Guide SIP/MGCP

26

 

 

Image 31
Contents VoIP Network Terminal IP250DImportant Safety Instructions 89/336/EEC Requirements of Part 15 FCC Rules European RequirementsContents Introduction to the IP250D VoIP Network Terminal Downloader Application IP250D Works Like a Telephone Introduction to the Teledex IP250D VoIP Network TerminalInstalling the IP250D Unpacking the IP250D Connecting the HandsetConnecting the IP250D to the Network Connecting a PC to the IP250DArranging the IP250D on the Desk Connecting a Headset to the IP250DMounting the IP250D on a Wall Home Configuring the IP250DVlan Settings LAN ConfigurationMgcp Configuration LAN Interface SettingsOOB Signalling Settings Mgcp SettingsHandset Settings SIP ConfigurationSIP Settings Localization Settings Codec ConfigurationSystem Configuration Security SettingsReset Configuration Download ConfigurationSnmp Settings Receiving a Call Using the IP250DTelephone Idle Incoming Call NotificationPlacing a Call Terminating a Call Dtmf SignalingHeadset and Speakerphone Usage Hold and Multiple Lines Teledex IP250D User’s Guide SIP/MGCP Forwarding ALL Calls Muting a CallTransferring a Call Redialing the Last Number DialedChanging Ringing Sounds Using the Msgs KEYConfiguring Local Speed Dial Numbers Making Conference CallsNetwork Troubleshooting Troubleshooting and CareBasic Troubleshooting Measures General TroubleshootingSymptom SIP-SPECIFIC Issues MGCP-SPECIFIC IssuesExecuting the Downloader Application Cleaning the IP250DUsing the Downloader Application Downloader ApplicationAppendix a Determining the IP Address Appendix B Safe Bootup ModesDownload of the new firmware image ’SAFE’ Modes on AN IP Phone Appendix C Restoring Factory DefaultsAppendix D Dial Plans Tone Configuration Appendix E Tone and Ring Cadence ConfigurationSample Dial Plans CUSTOM3 CUSTOM4 CUSTOM5 CUSTOM6 CUSTOM7 CUSTOM8 CUSTOM9 Example Tone ConfigurationsExample Ring Cadence Configuration Ring Cadence ConfigurationAppendix F IP250D Product Specifications Appendix G Product Support