Timex T100 user manual Location of fuses, Error Codes

Page 25

Location of fuses

The fuse panel is located on the back of the T100 in the lower left corner. To access fuses, disconnect the power from the clock and remove the screw that secures door. Replace blown fuse with only the same rated fuse. Do not

substitute.

1. Printer Head Fuse (1.5A DC 12V)

2. AC Fuse (1A AC 240V)

3. DC Fuse (2A DC 12V)

Error Codes

The T100 has built-in diagnostics to guide you in maintaining your time clock. These Error Codes, when occurring, will be seen on the display.

Code

Meaning of Error

Check

 

 

 

E-01

Clock motor or sensor failure

Unplug and reconnect power

 

 

cord or turn the program switch

 

 

on-off twice, letting the clock

 

 

readjust.

E-03

Card positioning

Verify correct card (T111)

E-05

Card does not feed correctly

Verify correct card (T111)

 

 

Re-insert card.

E-30

Printer head fails to return to

Contact dealer or Service Center

 

home position

 

E-33

Can’t change color

Check that the ribbon is

 

 

installed correctly.

E-35

The card can’t be returned

Make sure there are no

 

 

obstructions in card receiver

E-37

Sensor cannot locate card

Contact dealer or Service Center

E-38

Printer head jammed

Remove ribbon and check for

 

 

binding. Reinstall ribbon.

E-40

Wrong password entered

Enter the correct password or

 

 

refer to section “Setting the

 

 

Password”.

22

Image 25
Contents Page Time Clocks Table of Contents Overview IntroductionSpecifications FeaturesAccessories Template FrontBack III. Location of ComponentsDefault Settings IV. Quick Setting the T100Setting Programming Outline Setting the T100Programming Hints Enter Programming ModeTo Set Weekly Pay Periods Setting Pay Period and Current Print LineSetting 12- or 24- Hour Print Format Setting Year, Month, and Date Date may be set usingSetting the Day Change Time Setting the Minute Printing FormatSetting Time Zone Daylight Saving Time DST Inputting the Default PasswordIN1 OUT1 Setting Two-Color PrintingIN1 OUT1 Event Max Signal Tone Description Setting the Signal Tone TimesSetting Signal Duration Exiting Program Mode Changing the Default PasswordPunching Time Card VI. Operating the T100Wall Mounting Template VII. Installing the T100Wall-mounting Page Replacing the ribbon VIII. MaintenanceProblem Possible Cause Check IX. TroubleshootingLocation of fuses Error CodesWarranty Product Registration Card 06-0337-000 Rev. C