Unitech RS700 user manual Troubleshooting, Problem Solution

Page 56

Chapter 5

Troubleshooting

Unitech has a professional support team to answer any questions or technical related issues. If equipment problems occur please refer to the table below or contact a regional Unitech representative.

 

Problem

 

Solution

 

 

 

 

1.

Cannot Backup

Check if the Backup Battery Switch is on.

 

Data.

Send back to Unitech for RMA.

 

 

 

 

2.

Cannot Read a

Check whether the RFID Antenna is properly con-

 

Tag.

 

nected to the TNC Connector via Antenna Cable.

 

 

• Check whether the Antenna Port is correct.

 

 

• Check whether the tag is damaged.

 

 

• Check the software settings, e.g., reader status,

 

 

 

antenna port and etc.

 

 

Reset the RS700.

 

 

• Send back to Unitech for RMA.

 

 

 

 

3.

Cannot Charge

Check if the Backup Battery Switch is on.

 

the Backup

Send back to Unitech for RMA.

 

Battery.

 

 

 

 

 

 

4.

The USB

Reconnect the USB Cable.

 

Communication

Reset the RS700.

 

Fails.

Send back to Unitech for RMA.

 

 

 

 

5.

Cannot Reset

Make sure the Reset Button is pressed in.

 

the RS700.

Make sure the backup battery switch is turned off

 

 

 

when removing external power.

 

 

• Send back to Unitech for RMA.

 

 

 

 

48

Copyright 2009 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.

Image 56
Contents RS700 Smart Rfid Fixed Reader Page Preface About This ManualRegulatory Compliance Statements Federal Communication Commission Interference StatementFCC Caution FCC Radiation Exposure StatementStorage and Safety Notice Battery NoticesBattery Charge Notice Warranty Table of Contents Appendix a Introducing the RS700 FeaturesGetting Started Package Contents Component Description Tour of the RS700Front Panel Top Panel Bottom PanelConnect Power Using the Hardware Installing Wi-Fi AntennaInstalling Rfid Antenna Optional Pin Name Description Using the Gpio InterfaceGpio Pin Assignment Mounting the RS700 Performing a Hardware Reset Opening Smart-Reader Server Using Smart-Reader ServerMaking Rfid Applications Controlling Smart-Reader Server Remotely Installing Microsoft .NET FrameworkInstalling the Srsrc Program Using the Smart-Reader Server Remote Control Configuring Antenna Port Defining Smart Reader Behavior Creating a New EC Spec Start //spec1starttrigger Stop //spec1stoptrigger Specifying Report CriteriaDefining the EC Spec Urnepcpatgid-96*.*.* to match any GID-96 tagSubscribing the EC Spec Redefining the Subscription Viewing Data Collection Report Viewing Server Log Using the Application Programming InterfaceConnecting to BizTalk Server Making Rfid Applications Making Rfid Applications Check Add single device. Click Next Input the RS700s IP address and port number. Click Next Making Rfid Applications Making Rfid Applications Making Rfid Applications Connecting to Oracle Sensor Edge Server Click MyEdgeServer Click Change dispatcherMaking Rfid Applications Click Add new device Select Smart Reader Device Click MyEdgeServer → Groups → Default → RS700 Click Start all devices Obtaining an IP Address Advanced SettingsConnecting to a LAN Network Advanced Settings Setting the System TimeSetting up Ethernet connection Connecting to a Wlan Network Advanced Settings Advanced Settings Managing your Wireless Profiles Advanced Settings Advanced Settings Additional Capabilities Installing Microsoft ActiveSyncEstablishing Terminal-PC Connection Connecting the terminal to Your Computer Using Microsoft ActiveSync to Exchange Files On the computer, click My Computer → Mobile Device folderUsing Remote Control Click Start → Programs → ActiveSync Remote DisplayTroubleshooting Problem SolutionSystem Specification Appendix aSupport Region Web site