Viking PSFEM1xxxGQxxx manual Electrical Characteristics, Standby Immediate Command, Supply Voltage

Page 14

2.2.1 STANDBY IMMEDIATE Command

The Power-On-to-Ready time assumes a proper shutdown (power removal preceded by STANDBY IMMEDIATE command. A STANDBY IMMEDIATE before power down always performs a graceful shutdown and does not require the use of the hold-up circuit. Note that SMART attribute 174 "Unexpected Power Loss" records the number of non-graceful power cycle events.

Table 2-4: STANDBY IMMEDIATE Timing

Power Cycle Endurance

Min

Max

Unit

STANDBY IMMEDIATE to WE completed

-

72.9

ms

Notes:

1.From Standby Immediate command to NAND Write Protect enable.

2.3Electrical Characteristics

2.3.1 Absolute Maximum Ratings

Values shown are stress ratings only. Functional operation outside normal operating values is not implied. Extended exposure to absolute maximum ratings may affect reliability.

Table 2-5: Absolute Maximum Ratings

Description

Min

Max

Unit

Maximum Voltage Range for Vin

-0.2

6

V

Maximum Temperature Range

-40

85

c

 

2.3.2 Supply Voltage

 

 

 

 

 

 

The operating voltage is 5V.

 

 

 

 

 

 

Table 2-6: Operating Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description

 

Min

Max

Unit

 

Operating Voltage for 5.0 V (+/- 5%)

 

4.75

 

5.25

V

 

Table 2-8: Current Draw – SATA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mode

 

Typical1

 

 

Unit

 

 

Read/Writes (Average RMS)

 

215 / 310

 

 

mA

 

 

Idle

 

25

 

 

mA

 

 

Slumber

 

10

 

 

mA

 

 

Notes:

 

 

 

 

 

 

1. Measured using 16GB SLC, VRFEM1016GQCQS

Manual

PSFEM1xxxGQxxx

Revision B www.vikingtechnology.com

9/11/2014

Viking Technology

Page 14 of 33

Image 14
Contents Sata 3Gb/s Industrial Slim Sata Manual Revision History Date Revision Description Checked byLegal Information Part Numbers Application Capacity Sectors GB1 LBA Mode RangeUseable Addressable TechnologyProduct Pictures Slim Sata Top ViewManual PSFEM1xxxGQxxx 11/2014 Viking Technology Table of Contents ATA Commands Sata Commands Native Command Queuing NCQTable of Tables Table of FiguresFeatures IntroductionBlock Diagram High-Level Block Diagram for VRFEM1xxxGQxxxSata Interface Performance Product SpecificationsTiming Specifications TimingAbsolute Maximum Ratings Electrical CharacteristicsStandby Immediate Command Supply VoltageEnvironmental Conditions Power ConsumptionTemperature and Altitude Shock and VibrationData Security 10 Reliability SpecificationsReliability Parameter VRFEM1xxxGQxxxDimensions Mechanical InformationSignal and Power Description Tables Pin and Signal DescriptionsSlim Sata SSD Weight Serial ATA Connector Pin Signal DefinitionsSerial ATA Power Pin Definitions Command SetsATA Commands Supported ATA Commands1 48-Bit Address Command Set General Purpose Log Command Set ATA General Feature Command SetDevice Configuration Overlay Command Set Host Protected Area Command SetPower Management Command Set Security Mode Feature SetList of Device Identification Word Variable Default Value Description BothIdentify Device Data Word Variable Default Value Description Both Word Variable Default Value Description Both Capacity Word 1/Word 1 S.M.A.R.T. SupportCapacity specific Device Identification 2 S.M.A.R.T. Command Set Extended Smart Attributes S.M.A.R.T. Command SetValue hex Command Extended Smart Attribute TableExtended Smart Attribute Actual Data DataManual PSFEM1xxxGQxxx 11/2014 Viking Technology Native Command Queuing NCQ Off-line ModeSata Commands Supported S.M.A.R.T. Execute OFF-LINE Immediate SubcommandsReferences Glossary Term Definition