Viking manual Manual PSFEM1xxxGQxxx 11/2014 Viking Technology

Page 30

0

1

2

3

4

5

6

7

 

8

9

 

10

11

 

ID

Flag

Flag

Value

Worse

 

 

DATA

 

 

 

 

 

Threshold

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B1h

00h

00h

00h

00h

Fla7

0

0

 

0

0

 

0

0

00h

B5h

12h

00h

64h

64h

Program Fail

0

 

0

0

 

0

0

00h

Count

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B6b

32h

00h

00h

00h

Erase Fail Count

0

 

0

0

 

0

0

00h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B7h

12h

00h

64h

64h

Fla4

Max Erase Count

Min Erase

0

64h

 

Count

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BBh

32h

00h

64h

64h

Uncorrectable

0

 

0

0

 

0

0

00h

Count

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C0h

12h

00h

64h

64h

Number of Accidental Power

 

0

 

0

0

00h

 

Loss Count

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100-

100-

 

 

 

 

 

 

 

 

 

 

C2h

23h

00h

Current

Highest

Current Temp

Lowest Temp

Highest Temp

0

1Eh

 

 

 

Temp

Value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C4b

13h

00h

Fla8

Fla8

B (Note)

A (Note)

 

C (Note)

 

0Ah

 

 

 

 

 

 

 

 

 

 

 

 

 

C7h

32h

00h

64h

64h

CRC Error Count

0

 

0

0

 

0

0

00h

DAh

0Bh

00h

64h

64h

 

CRC Error Count

 

0

 

0

0

32h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E7h

13h

00h

64h

64h

Fla9

0

0

 

0

0

 

0

0

00h

 

 

 

 

 

Read

 

 

 

 

 

 

 

 

 

E8h

0Bh

00h

64h

64h

Fail

0

0

 

0

0

 

0

0

00h

 

 

 

 

 

Count

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E9h

0Bh

00h

64h

64h

 

Lifetime Writes to Flash by Sector

 

 

0

00h

F1h

12h

00h

64h

64h

 

Lifetime Writes from Host by Sector

 

 

0

00h

F2h

12h

00h

64h

64h

 

Lifetime Reads from Host by Sector

 

 

0

00h

F6h

12h

00h

64h

64h

 

 

Total Erase Count

 

 

 

0

00h

Notes:

Formula:

Fla4 = Total Erase Count / disk Total Blocks (average Erase Count

Fla6 = (100 * (D- Total Bad Block Count) / (D-E)) Max = 100, Min = 1

Fla7 = 100*((Max Erase Count- F1a4)/Flash PE Cycle (MLC 3000, SLC 10000))

Fla8 = (100*(A-C))/A (Note) Min = 1

Fla9 = 100- (100*(F1a4/ Flash PE Cycle (MLC 3000, SLC 10000)

Fla10 = (100*G)/F Max = 100, Min = 1

Manual

PSFEM1xxxGQxxx

Revision B www.vikingtechnology.com

9/11/2014

Viking Technology

Page 30 of 33

Image 30
Contents Sata 3Gb/s Industrial Slim Sata Manual Revision History Date Revision Description Checked byLegal Information Part Numbers Application Capacity Sectors GB1 LBA Mode RangeUseable Addressable TechnologyProduct Pictures Slim Sata Top ViewManual PSFEM1xxxGQxxx 11/2014 Viking Technology Table of Contents ATA Commands Sata Commands Native Command Queuing NCQTable of Tables Table of FiguresFeatures IntroductionBlock Diagram High-Level Block Diagram for VRFEM1xxxGQxxxSata Interface Performance Product SpecificationsTiming Specifications TimingAbsolute Maximum Ratings Electrical CharacteristicsStandby Immediate Command Supply VoltageEnvironmental Conditions Power ConsumptionTemperature and Altitude Shock and VibrationData Security 10 Reliability SpecificationsReliability Parameter VRFEM1xxxGQxxxDimensions Mechanical InformationSignal and Power Description Tables Pin and Signal DescriptionsSlim Sata SSD Weight Serial ATA Connector Pin Signal DefinitionsSerial ATA Power Pin Definitions Command SetsATA Commands Supported ATA Commands1 48-Bit Address Command Set General Purpose Log Command Set ATA General Feature Command SetDevice Configuration Overlay Command Set Host Protected Area Command SetPower Management Command Set Security Mode Feature SetWord Variable Default Value Description Both Identify Device DataList of Device Identification Word Variable Default Value Description Both Word Variable Default Value Description Both 1 S.M.A.R.T. Support Capacity specific Device IdentificationCapacity Word 1/Word 2 S.M.A.R.T. Command Set Extended Smart Attributes S.M.A.R.T. Command SetValue hex Command Extended Smart Attribute TableExtended Smart Attribute Actual Data DataManual PSFEM1xxxGQxxx 11/2014 Viking Technology Native Command Queuing NCQ Off-line ModeSata Commands Supported S.M.A.R.T. Execute OFF-LINE Immediate SubcommandsReferences Glossary Term Definition