Viking PSFEM1xxxGQxxx manual Extended Smart Attribute Actual Data

Page 29

SMART Attribute

 

ID

Description

B6h

Erase Failure Block Count

B7h

Erase Count

BBh

Reported Uncorrectable Errors

C0h

Unexpected Power Loss Count

C2h

Temperature (only Toshiba or thermo sensor embedded)

C4h

Max Bad Block Count

C7h

Ultra CRC Error Count

 

Number of accumulation CRC error (read/write data FIS CRC

DAh

error)

E7h

Wear Range delta/SSD life remaining

E8h

Read Failure Block Count

E9h

Lifetime Writes to Flash

F1h

Host Writes

F2h

Host Reads

F6h

Total Erase Count

Table 5-6: Extended SMART Attribute Actual Data

0

1

2

3

4

5

 

6

7

 

8

9

 

10

11

 

ID

Flag

Flag

Value

Worse

 

 

 

DATA

 

 

 

 

 

Threshold

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01h

0Bh

00h

64h

64h

0

 

0

Uncorrectable ECC

0

 

0

0

32h

 

Count

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

05h

13h

00h

64h

64h

0

 

0

0

 

0

0

 

0

0

32h

09b

12h

00h

64h

64h

Power on hour

0

 

0

0

 

0

0

00h

0Ch

12h

00h

64h

64h

 

 

Power on/off cycles

 

0

 

0

0

00h

A8h

12h

00h

64h

64h

 

SATA PHY error count

 

0

 

0

0

00h

A9h

13h

00h

Fla6

Fla6

 

E (Note)

D (Note)

 

Total Bad

0

0Ah

 

 

Block Count

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AAh

02h

00h

Fla10

Fla10

Early Bad Block

0

 

0

Later Bad

0

0Ah

 

 

Block

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ACh

32h

00h

64h

64h

Erase Fail Count

0

 

0

0

 

0

0

00h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ADh

12h

00h

64h

64h

Max Erase Count

Ave Erase Count

0

 

0

0

00h

(Fla4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Manual

PSFEM1xxxGQxxx

Revision B www.vikingtechnology.com

9/11/2014

Viking Technology

Page 29 of 33

Image 29
Contents Sata 3Gb/s Industrial Slim Sata Manual Date Revision Description Checked by Revision HistoryLegal Information Useable Addressable GB1 LBA Mode RangePart Numbers Application Capacity Sectors TechnologySlim Sata Top View Product PicturesManual PSFEM1xxxGQxxx 11/2014 Viking Technology Table of Contents Sata Commands Native Command Queuing NCQ ATA CommandsTable of Figures Table of TablesIntroduction FeaturesHigh-Level Block Diagram for VRFEM1xxxGQxxx Block DiagramSata Interface Timing Specifications Product SpecificationsPerformance TimingStandby Immediate Command Electrical CharacteristicsAbsolute Maximum Ratings Supply VoltageTemperature and Altitude Power ConsumptionEnvironmental Conditions Shock and VibrationReliability 10 Reliability SpecificationsData Security Parameter VRFEM1xxxGQxxxMechanical Information DimensionsSlim Sata SSD Weight Pin and Signal DescriptionsSignal and Power Description Tables Serial ATA Connector Pin Signal DefinitionsATA Commands Command SetsSerial ATA Power Pin Definitions Supported ATA Commands1 48-Bit Address Command Set Device Configuration Overlay Command Set ATA General Feature Command SetGeneral Purpose Log Command Set Host Protected Area Command SetSecurity Mode Feature Set Power Management Command SetList of Device Identification Word Variable Default Value Description BothIdentify Device Data Word Variable Default Value Description Both Word Variable Default Value Description Both Capacity Word 1/Word 1 S.M.A.R.T. SupportCapacity specific Device Identification 2 S.M.A.R.T. Command Set Value hex Command S.M.A.R.T. Command SetExtended Smart Attributes Extended Smart Attribute TableData Extended Smart Attribute Actual DataManual PSFEM1xxxGQxxx 11/2014 Viking Technology Sata Commands Off-line ModeNative Command Queuing NCQ Supported S.M.A.R.T. Execute OFF-LINE Immediate SubcommandsReferences Term Definition Glossary