Viking PSFEM1xxxGQxxx Useable Addressable, Part Numbers Application Capacity Sectors, Technology

Page 4

Ordering Information: Slim SATA SSD Solid-State Drive

 

SATA

 

Raw

Useable

Addressable

NAND

 

Part Numbers

Application

Capacity

Capacity

Sectors in

Temperature

Interface

Technology

 

 

(GB)

(GB)1

LBA Mode

Range

VRFEM1008GQCQMxx

3Gbps

Industrial

8

8

15,625,000

MLC

0 to 70c

VRFEM1016GQCQMxx

3Gbps

Industrial

16

16

31,277,232

MLC

0 to 70c

VRFEM1032GQCRMxx

3Gbps

Industrial

32

32

62,533,296

MLC

0 to 70c

VRFEM1064GQCSMxx

3Gbps

Industrial

64

64

125,045,424

MLC

0 to 70c

VRFEM1008GQIQMxx

3Gbps

Industrial

8

8

15,625,000

MLC

-40 to 85c

VRFEM1016GQIQMxx

3Gbps

Industrial

16

16

31,277,232

MLC

-40 to 85c

VRFEM1032GQIRMxx

3Gbps

Industrial

32

32

62,533,296

MLC

-40 to 85c

VRFEM1064GQISMxx

3Gbps

Industrial

64

64

125,045,424

MLC

-40 to 85c

VRFEM14096QCGSxx

3Gbps

Industrial

4

4

7,812,500

SLC

0 to 70c,

VRFEM18192QCHSxx

3Gbps

Industrial

8

8

15,625,000

SLC

0 to 70c

VRFEM18192QCQQSxx

3Gbps

Industrial

8

8

15,625,000

SLC

0 to 70c

VRFEM1016GQCQSxx

3Gbps

Industrial

16

16

31,277,232

SLC

0 to 70c

VRFEM1032GQCRSxx

3Gbps

Industrial

32

32

62,533,296

SLC

0 to 70c

VRFEM1064GQCSSxx

3Gbps

Industrial

64

64

125,045,424

SLC

0 to 70c

VRFEM14096QIGSxx

3Gbps

Industrial

4

4

7,812,500

SLC

-40 to 85c

VRFEM18192QIHSxx

3Gbps

Industrial

8

8

15,625,000

SLC

-40 to 85c

VRFEM18192QIQQSxx

3Gbps

Industrial

8

8

15,625,000

SLC

-40 to 85c

VRFEM1016GQIQSxx

3Gbps

Industrial

16

16

31,277,232

SLC

-40 to 85c

VRFEM1032GQIRSxx

3Gbps

Industrial

32

32

62,533,296

SLC

-40 to 85c

VRFEM1064GQISSxx

3Gbps

Industrial

64

64

125,045,424

SLC

-40 to 85c

Notes:

1)Usable capacity based on a level of over-provisioning applied to wear leveling, bad sectors, index tables etc.

2)Higher capacity points may be available based on customer application. Consult your local Viking Field Application Engineer.

3)SSD’s ship unformatted from the factory unless otherwise requested.

4)1 GB = 1,000,000,000 Byte

5)One Sector = 512 Byte.

6)Contact Viking for the characters that “x” and “y” represent in the part number.

7)xx is a wild card to indicate customer specific BOM, NAND configuration and/or manufacturing location

Manual

PSFEM1xxxGQxxx

Revision B www.vikingtechnology.com

9/11/2014

Viking Technology

Page 4 of 33

Image 4
Contents Sata 3Gb/s Industrial Slim Sata Manual Revision History Date Revision Description Checked byLegal Information GB1 LBA Mode Range Useable AddressablePart Numbers Application Capacity Sectors TechnologyProduct Pictures Slim Sata Top ViewManual PSFEM1xxxGQxxx 11/2014 Viking Technology Table of Contents ATA Commands Sata Commands Native Command Queuing NCQTable of Tables Table of FiguresFeatures IntroductionBlock Diagram High-Level Block Diagram for VRFEM1xxxGQxxxSata Interface Product Specifications Timing SpecificationsPerformance TimingElectrical Characteristics Standby Immediate CommandAbsolute Maximum Ratings Supply VoltagePower Consumption Temperature and AltitudeEnvironmental Conditions Shock and Vibration10 Reliability Specifications ReliabilityData Security Parameter VRFEM1xxxGQxxxDimensions Mechanical InformationPin and Signal Descriptions Slim Sata SSD WeightSignal and Power Description Tables Serial ATA Connector Pin Signal DefinitionsCommand Sets ATA CommandsSerial ATA Power Pin Definitions Supported ATA Commands1 48-Bit Address Command Set ATA General Feature Command Set Device Configuration Overlay Command SetGeneral Purpose Log Command Set Host Protected Area Command SetPower Management Command Set Security Mode Feature SetIdentify Device Data Word Variable Default Value Description BothList of Device Identification Word Variable Default Value Description Both Word Variable Default Value Description Both Capacity specific Device Identification 1 S.M.A.R.T. SupportCapacity Word 1/Word 2 S.M.A.R.T. Command Set S.M.A.R.T. Command Set Value hex CommandExtended Smart Attributes Extended Smart Attribute TableExtended Smart Attribute Actual Data DataManual PSFEM1xxxGQxxx 11/2014 Viking Technology Off-line Mode Sata CommandsNative Command Queuing NCQ Supported S.M.A.R.T. Execute OFF-LINE Immediate SubcommandsReferences Glossary Term Definition