Read Mode Settings Continued:

 

read time 0 second

 

Z1

 

 

 

 

 

read time 1 second

 

Z2

 

 

 

 

 

read time 2 seconds

default

Z3

 

 

 

 

 

read time 3 seconds

 

Z!

 

 

 

 

 

read time 4 seconds

 

Z5

 

 

 

 

Normal

read time 5 seconds

 

Z6

Read Time

read time 6 seconds

 

Z7

 

 

 

 

 

 

 

read time 7 seconds

 

Z8

 

 

 

 

 

read time 8 seconds

 

Z9

 

 

 

 

 

read time 9 seconds

 

Z:

 

 

 

 

 

read time * 10

 

ZN

 

 

 

 

 

read time indefinitely

 

ZM

 

 

 

 

 

 

 

 

 

read 1 time, redundancy = 0

 

Y1

 

 

 

 

 

read 2 time, redundancy = 1

default

Y2

 

 

 

 

 

read 3 time, redundancy = 2

 

Y3

 

 

 

 

 

read 4 time, redundancy = 3

 

Y!

 

 

 

 

Redundancy

read 5 time, redundancy = 4

 

CT

 

 

 

 

 

read 6 time, redundancy = 5

 

CU

 

 

 

 

 

read 7 time, redundancy = 6

 

CV

 

 

 

 

 

read 8 time, redundancy = 7

 

CW

 

 

 

 

 

read 9 time, redundancy = 8

 

CX

 

 

 

 

Redundancy is the number of times that the label has to be scanned in addition to the first scan.

Positive and Negative Codes

positive bar codes (black on white)

default

W3

 

 

 

negative bar codes (white on black)

 

W!

 

 

 

positive and negative bar codes

 

W5

 

 

 

A-47

Image 53
Contents 5202D Scanner USA Headquarters European Distribution Office US Toll Free Worth Data Inc Worth Data, IncTable of Contents Introduction Installation Configuration UPC 1D CodesOther Options 2D codesSet to factory default Y5E Y5CY5D EAN EAN SettingsY5H Y5FY5G Code Code 39 SettingsItalian Pharmaceutical Options Enable Disable Codabar Codabar SettingsCodabar Settings Code 128 Settings Symbology Exclusive Enable Disable Code 93 default enable Code 93 SettingsCMG CMC CMD CMBCMH CMI5 and S-Code 5 and S-Code SettingsY5L Y5MMSI / Plessey MSI / Plessey SettingsUK / Plessey UK / Plessey SettingsSymbology Exclusive Enable Disable Postnet default disable Postnet SettingsIntelligent Mail Bar Code Intelligent Mail Bar Code SettingsSymbology Exclusive Enable Disable Imbc default disable CD7 CDJ CDV GS1 DataBar SettingsGS1 DataBar Korean Postal Authority Korean Postal Authority Code SettingsSymbology Exclusive Enable Disable Iata default enable Iata SettingsTri-Optic Tri-Optic SettingsSymbology Exclusive Enable Disable Tri-Optic default enable Telepen Telepen SettingsSymbology Exclusive Enable Disable Telepen default enable JPN Customer Bar Code JPN SettingsSymbology Exclusive Enable Disable JPN default disable Start Setup End Setup Symbology Exclusive Enable Disable CD5 CDH CDT Maxi Code Maxi Code SettingsSymbology Exclusive Enable Disable Maxi Code default enable QR Code QR Code SettingsSymbology Exclusive Enable Disable QR Code default enable Micro QR Micro QR SettingsSymbology Exclusive Enable Disable Micro QR default enable Aztec Code Aztec Code SettingsAztec Runes Aztec Runes SettingsData Matrix Data Matrix SettingsCD1 CDD CDP CH3 CH1 CH2Codablock F Codablock F SettingsChinese Sensible Code Chinese Sensible Code SettingsSymbology Exclusive Enable Disable Chinese Sensible Code All Codes All Codes SettingsCDB CDN CDZ CDC CDONumber of Characters Number of Characters SettingsCharacter Length Settings Composite Codes Output Format Settings Case Conversion SettingsString Options Output FormatYNY YPY Prefix / Suffix CommandsCME CMF E6J E6KE5T E5U E7E E7FCG1 CG2 E5O E5PPrefix / Suffix Ascii Value Table Code Identification / Length Settings EAN-8 Postnet Worth Data Code ID Prefix / Suffix ValuesCollective Reading E1V E1U E1W E1XRead Mode Settings Read ModeYNK YNGYNI Read Mode Settings YTI YTDFC1 FC2EN2 EN3EN1 F9LIndicator Settings FBS DiagnosticsDiagnostic Codes Windows XP Appendix BWindows 98SE & ME WindowsWindows 7 & Vista