Imager Settings:
Illumination Mode
disable LED illumination |
| E!B |
|
|
|
enable LED illumination | default | E!: |
|
|
|
LED illumination alternating |
| E!C |
|
|
|
Aiming On/Off
disable laser aiming and LED illumination |
| E!D |
|
|
|
enable laser aiming | default | E!E |
|
|
|
disable laser aiming |
| E!F |
|
|
|
Central Reading
enable central reading |
| E11 | |
(read only a code that the laser aims at) |
| ||
|
|
| |
disable central reading | default | E1[ | |
(read the entire image) | |||
|
| ||
|
|
|
1D Code Decode Mode
careful mode (good for hard to read codes) |
| EN! |
|
|
|
standard mode | default | EN3 |
|
|
|
| EN2 | |
|
|
|
quick mode (good for easy to read codes) |
| EN1 |
|
|
|
LCD Display Scanning
disable scanning from LCD display | default | E!J |
|
|
|
enable scanning from LCD display |
| E!K |
|
|
|
Auto Focus Mode
AF system = laser and contrast | default | F9L |
|
|
|
AF system = contrast only |
| F9M |
|
|
|
AF system = laser only |
| F9N |
|
|
|
Note: Normally laser ranging is used for reading labels. In case it cannot be used in a
Fixed Focus Mode
short range = 90mm
medium range = 163mm
long range = 880mm