A&D AD-4212B-101/102/201/301, AD-4212A/B Transmitting all memory data at one time

Page 58

Transmitting all memory data at one time

Confirm that the “Serial interface ( 5if )” parameters are set properly. For details, refer to “10. FUNCTION TABLE” and “17. CONNECTION TO PERIPHERAL EQUIPMENT”.

1

Press and hold the

PRINT

key until

reCall

 

is displayed, then release the key.

2

Press the

 

 

 

key to display

 

 

.

 

 

SAMPLE

 

 

out

3

Press the

 

key to display

 

 

 

with “no” blinking.

PRINT

Sout no

 

5

Press the

 

key to display

 

 

 

 

 

with “go” blinking.

RE-ZERO

 

 

out

 

go

6Press the PRINT key to transmit all data using the RS-232C interface.

7The balance displays Clear when all data is transmitted. Press the CAL key to return to the weighing mode.

Deleting all memory data at one time

1

Press and hold the

PRINT

key until

 

reCall

is displayed, then release the key.

2

Press the

 

 

 

 

key several times to display

 

.

SAMPLE

 

Clear

3

Press the

 

 

key to display

 

 

 

 

with “no” blinking.

PRINT

SClr no

4

Press the

 

 

key to display

 

 

 

with “go” blinking.

RE-ZERO

SClr go

 

5

Press the

 

 

key to delete all data

 

 

 

PRINT

 

 

 

6

The balance displays

 

, then

 

 

when all data is deleted.

end

 

reCall

7

Press the

 

key to return to the weighing mode.

CAL

56

Image 58
Contents 212 B 1WMPD4001448CPage Contents ID Number and GLP Report TERMS/INDEX Features IntroductionCompliance with EMC Directives ComplianceCompliance with FCC Rules Windows is a registered trademark of Microsoft CorporationUnpacking Unpacking the BalanceRear of the display unit Accessories AC adapter ID labelPlace the breeze break on the weighing pan so Installing the BalanceHow to install the breeze break That it fits over the dust guardHow to disconnect the cable from the weighing unit Rear of the weighing unitPrecautions Before UseWhen Building into a System Lighter heavier than the true weight. This During Use Power SupplyAfter Use Processing indicator Display Symbols and KEY OperationDisplay symbols Stabilization indicatorUnits Weighing UnitsProgrammable-unit Minimum Capacity Capacity Minimum DisplayChanging the Unit Basic Operation Gram Mode WeighingPrecision range/standard range value Smart Range Function01 mg 0.1 mg Standard range Cond Changing the Weighing SpeedOperation Sensitive valueCalibration test CalibrationCalibration DisplayCalibration From previous Key until CCout Usable weights is shown on page 21, pressCalibration Test Return to CCFrom previous Permit or Inhibit Function Switch and InitializationSwitches For details, refer to 20. Extended FunctionsInitializing the Balance Be sure to calibrate the balance after initializationDisplay and Keys Function TableStructure and Sequence of the Function Table ExampleDetails of the Function Table Cpout Cp-t Output SettingData output mode Only the AD-4212B seriesInterval time Auto print polarityData memory Time/Date outputID number setting TimeoutAK, Error code Baud rateStability band width 5t-b Description of the Class Environment, DisplayCondition Cond Hold function Hold Animal weighing mode, AD-4212A onlyDisplay refresh rate 5pd Capacity indicator g5iZero tracking trc Decimal point pntStream mode Description of the Item Data output modeKey mode Tare at start p-trInterval memory mode Key mode BKey mode C Description of the Item Data formatMT format 5if type DP Dump print format 5if typeKF format 5if type NU numerical format 5if typeData number dout d-no Description of the Data Format Added to the Weighing DataID number Dout 5-id Date dout 5-td 2 orData Format Examples Positive errorNegative error Space 20hClock and Calendar Function Setting the time with part of the digits blinkingConfirming the time Confirming the date Set the date using the following keysQuitting the operation Three-level comparison results Comparator FunctionFive-level comparison results Setting the upper/lower limit values Indicates a space 20hWhen five-level comparison is selected When three-level comparison is selectedConfirming the upper/lower limit values Adding the comparison results AD-4212A only ID Number and GLP Report Setting the ID NumberDisplay character set Calibration report When the setting is infoGLP Report Set the following parameters to output the reportCalibration test report using an external weight Weighing data Title block and end blockEnd block Selecting the counting mode Counting Mode PCStoring a sample unit mass Counting mode using the Acai function Counting operationStoring the 100% reference mass Selecting the percent modeReading the percentage Releasing Clr Balance displays End Returns to the weighing modeData Memory Key until SClr noKey is pressed while the displayed value is Memory for Weighing DataStoring the weighing data Stable, the balance stores the weighing dataPress the CAL key to return to the weighing mode Setting the function tableRecalling the memory data Transmitting all memory data at one time Deleting all memory data at one timeTransmitting the memory data Memory for Calibration and Calibration Test DataStoring the calibration and calibration test data Deleting the memory dataRecalling the unit mass Memory for Unit Mass in the Counting ModeKey To cancel the operation and go to step Key To increase the unit mass number by oneMemory for Upper/lower limit values Inputting the upper/lower limit values 3-level comparison Switching the upper/lower limit values 3-level comparison Confirming the coefficient Setting the coefficientUsing the function Selecting the programmable-unitSub 25 pin numbers Sub 25 pin assignments RS-232CExternal contact input Use a shieldedCable Use a shielded cableAD-8121B settings Mode PrtWhen multiple lines are to be printed, set the parameter to Connection to Peripheral EquipmentRsCom Using Windows Communication Tools WinCTConnection to a Computer RsKeyUsing the WinCT software, the balance can do the following Commands to query weighing data CommandsCommand List Commands to control the balanceAcknowledge Code and Error Codes Control Using CTS and RTS Settings Related to RS-232CConnector Pin Nos. and Specifications CablePin assignments and I/O logic Timing chart OP-01 installation procedureOn, T off 100 m sec or longer Extended Functions AD-4212A only Page Description of Averaging range and Averaging time Averaging range f1-b and averaging time f1-tCheck the balance performance using the self-check function MaintenanceTroubleshooting Checking the Balance Performance and EnvironmentWeighing method Operating environmentSample and container Error Codes Memory type error Unit mass errorClock battery error EC, E00 Communications errorAsking For Repair Specifications Power receptacle type Power consumption Calibration weight providedDisplay Dimensions 237 W × 150 D × 155 H mm Mass Counting Minimum unit mass ModeDesigning a Special Weighing PAN Using the pan supportPan support can be removed Shock absorber specifications Using the pan bossPan boss can not be removed AD-4212A-100 Mass of the special weighing pan AD-4212A series balanceAD-4212A-200 AD-4212A-600 AD-4212A-1000Mass of the special weighing pan AD-4212B series balance AD-4212B-101/102AD-4212B-201 AD-4212B-301Installing the Display Unit Installing in a panelAttaching the Mounting Fixtures Attachment ProcedureSecure the weighing unit from above Same for all the models External DimensionsDisplay unit Weighing unitWeighing unit with the mounting fixtures attached AD-1683 DC static eliminator OptionsAD-8121B Printer AD-1684 Electrostatic field meterOP-08 Ethernet interface OP-20 Metal leveling footTerms TERMS/INDEXIndex Cp fnc BepCl adj Cp HHOff G5iPnt Rng5t-b 5pdTrc Memo

AD-4212A-100/200/600/1000, AD-4212A/B, AD-4212B-101/102/201/301 specifications

The A&D AD-4212 series, including models AD-4212B-101, AD-4212B-102, AD-4212B-201, AD-4212B-301, AD-4212A/B, and AD-4212A-100/200/600/1000, represents a significant advancement in precision weighing technology. A&D Company, a leader in the field of measurement and weighing solutions, has equipped these models with various features that cater to diverse industrial needs.

One of the standout characteristics of the AD-4212 series is its high precision load cell technology. This technology enables accurate measurements with a resolution that can reach up to 0.01 grams, making it suitable for industries where precision is paramount, such as pharmaceuticals and laboratories. Additionally, the series boasts an impressive overload protection feature, allowing it to handle weights significantly above its rated capacity without sustaining damage.

Durability and user-friendliness are also top priorities for the AD-4212 models. The devices are constructed using high-quality materials that ensure longevity, even in demanding environments. The intuitive user interface includes a large, easy-to-read LCD display, which enhances usability by allowing operators to view measurements and settings effortlessly.

Another essential feature of the AD-4212 series is its versatility in connectivity. These models support multiple communication protocols, including USB and RS-232, enabling seamless integration with computers and other devices for data output and printing. This connectivity capability facilitates streamlined operations in various settings, allowing for efficient data management and record-keeping.

User customization is also a significant aspect of these models. The AD-4212 series allows users to calibrate the devices according to their specific requirements, ensuring that they can tailor the performance to suit varied applications. Moreover, the models come with built-in functions for tare, hold, counting, and statistical calculations, making them extremely flexible for different weighing scenarios.

Energy efficiency is another noteworthy consideration in the design of the AD-4212 series. These models often feature automatic shut-off functions that help conserve energy, extending battery life and reducing operating costs. The combination of these technologies and characteristics makes the A&D AD-4212 series an exemplary choice for professionals seeking reliable and accurate weighing solutions across various industries. Overall, the AD-4212 models exemplify A&D's commitment to quality, precision, and user satisfaction.