A&D AD-4212A-100/200/600/1000, AD-4212A/B, AD-4212B-101/102/201/301 instruction manual Terms/Index

Page 98

 

29. TERMS/INDEX

 

 

Terms

 

Stable value

The weight data when the stabilization indicator appears.

Environment

Ambient conditions such as vibration, drafts, temperature, static electricity or

 

magnetic fields which affect the weighing operation.

Store

To save the weighing data, unit mass, calibration data or upper/lower limit values

 

using the data memory function.

Calibration

Adjustment of the balance so that it can weigh accurately.

Output

To output the weighing data using the RS-232C interface.

Zero point

A weighing reference point or the zero display. Usually refers to the value

 

displayed when nothing is on the weighing pan.

Data number

Numbers assigned sequentially when weighing data or unit weight is stored.

Digit

Unit of digital resolution. Used for the balance, the minimum displayable weighing value

Tare

To cancel the weight of a container which is not included in the weighing data.

Mode

Balance operational function.

Re-zero

To set the display to zero.

GLP

Good Laboratory Practice.

Repeatability

Variation in measured values obtained when the same weight is placed and

 

removed repetitively. Usually expressed as a standard deviation.

 

e.g. Standard deviation=1 digit: This means that measured values fall within ±1

 

digit in the frequency of about 68%.

Stabilization time Time required after a sample being placed, until the stabilization indicator illuminates and the weighing data is displayed.

Sensitivity drift An affect that a change in temperature causes to the weighing data. Expressed as temperature coefficient.

e.g. Temperature coefficient = 2 ppm/°C : If a load is 100 g and the temperature changes by 10°C, the value displayed changes by the following value. 0.0002%/°C x 10°C x 100 g = 2 mg

Index

Keys and symbols

Carriage return

39

 

 

ON/OFF key

 

14

 

 

 

Line feed

39

 

 

PRINT key

14

 

 

Space mark

39

 

 

RE-ZERO key

14

 

Comparator indicators

14

 

 

SAMPLE key

 

14

 

 

Weighing speed indicators

14

100% reference mass

52

 

Interval memory active indicator

14

 

 

 

 

 

 

 

Interval memory standby indicator

14

- A -

 

 

 

 

 

 

A&D standard format

36

 

Processing indicator

14

AC adapter

9, 10, 13, 34, 41, 83

 

Stabilization indicator

14

ACAI

 

51

 

Standby indicator

14

Acknowledge code

69

 

CAL key

14

AD-1683

DC static eliminator

11, 94

 

MODE key

14

AD-1684

Electrostatic field meter

94

96

Image 98
Contents 212 B 1WMPD4001448CPage Contents ID Number and GLP Report TERMS/INDEX Features IntroductionCompliance with EMC Directives ComplianceCompliance with FCC Rules Windows is a registered trademark of Microsoft CorporationRear of the display unit Unpacking the BalanceUnpacking Accessories AC adapter ID labelPlace the breeze break on the weighing pan so Installing the BalanceHow to install the breeze break That it fits over the dust guardHow to disconnect the cable from the weighing unit Rear of the weighing unitPrecautions Before UseWhen Building into a System Lighter heavier than the true weight. This After Use Power SupplyDuring Use Processing indicator Display Symbols and KEY OperationDisplay symbols Stabilization indicatorProgrammable-unit Weighing UnitsUnits Minimum Capacity Capacity Minimum DisplayChanging the Unit Basic Operation Gram Mode Weighing01 mg 0.1 mg Standard range Smart Range FunctionPrecision range/standard range value Cond Changing the Weighing SpeedOperation Sensitive valueCalibration test CalibrationCalibration DisplayCalibration From previous Key until CCout Usable weights is shown on page 21, pressCalibration Test Return to CCFrom previous Permit or Inhibit Function Switch and InitializationSwitches For details, refer to 20. Extended FunctionsInitializing the Balance Be sure to calibrate the balance after initializationDisplay and Keys Function TableStructure and Sequence of the Function Table ExampleDetails of the Function Table Cpout Cp-t Output SettingData output mode Only the AD-4212B seriesInterval time Auto print polarityData memory Time/Date outputID number setting TimeoutAK, Error code Baud rateStability band width 5t-b Description of the Class Environment, DisplayCondition Cond Hold function Hold Animal weighing mode, AD-4212A onlyDisplay refresh rate 5pd Capacity indicator g5iZero tracking trc Decimal point pntStream mode Description of the Item Data output modeKey mode Tare at start p-trInterval memory mode Key mode BKey mode C Description of the Item Data formatMT format 5if type DP Dump print format 5if typeKF format 5if type NU numerical format 5if typeData number dout d-no Description of the Data Format Added to the Weighing DataID number Dout 5-id Date dout 5-td 2 orData Format Examples Positive errorNegative error Space 20hConfirming the time Setting the time with part of the digits blinkingClock and Calendar Function Quitting the operation Set the date using the following keysConfirming the date Five-level comparison results Comparator FunctionThree-level comparison results Setting the upper/lower limit values Indicates a space 20hConfirming the upper/lower limit values When three-level comparison is selectedWhen five-level comparison is selected Adding the comparison results AD-4212A only Display character set Setting the ID NumberID Number and GLP Report Calibration report When the setting is infoGLP Report Set the following parameters to output the reportCalibration test report using an external weight End block Title block and end blockWeighing data Storing a sample unit mass Counting Mode PCSelecting the counting mode Counting mode using the Acai function Counting operationReading the percentage Selecting the percent modeStoring the 100% reference mass Releasing Clr Balance displays End Returns to the weighing modeData Memory Key until SClr noKey is pressed while the displayed value is Memory for Weighing DataStoring the weighing data Stable, the balance stores the weighing dataRecalling the memory data Setting the function tablePress the CAL key to return to the weighing mode Transmitting all memory data at one time Deleting all memory data at one timeTransmitting the memory data Memory for Calibration and Calibration Test DataStoring the calibration and calibration test data Deleting the memory dataRecalling the unit mass Memory for Unit Mass in the Counting ModeKey To cancel the operation and go to step Key To increase the unit mass number by oneMemory for Upper/lower limit values Inputting the upper/lower limit values 3-level comparison Switching the upper/lower limit values 3-level comparison Confirming the coefficient Setting the coefficientUsing the function Selecting the programmable-unitSub 25 pin numbers Sub 25 pin assignments RS-232CExternal contact input Use a shieldedCable Use a shielded cableAD-8121B settings Mode PrtWhen multiple lines are to be printed, set the parameter to Connection to Peripheral EquipmentRsCom Using Windows Communication Tools WinCTConnection to a Computer RsKeyUsing the WinCT software, the balance can do the following Commands to query weighing data CommandsCommand List Commands to control the balanceAcknowledge Code and Error Codes Control Using CTS and RTS Settings Related to RS-232CConnector Pin Nos. and Specifications CablePin assignments and I/O logic On, T off 100 m sec or longer OP-01 installation procedureTiming chart Extended Functions AD-4212A only Page Description of Averaging range and Averaging time Averaging range f1-b and averaging time f1-tCheck the balance performance using the self-check function MaintenanceTroubleshooting Checking the Balance Performance and EnvironmentSample and container Operating environmentWeighing method Error Codes Memory type error Unit mass errorClock battery error EC, E00 Communications errorAsking For Repair Specifications Power receptacle type Power consumption Calibration weight providedDisplay Dimensions 237 W × 150 D × 155 H mm Mass Counting Minimum unit mass ModePan support can be removed Using the pan supportDesigning a Special Weighing PAN Pan boss can not be removed Using the pan bossShock absorber specifications AD-4212A-200 Mass of the special weighing pan AD-4212A series balanceAD-4212A-100 AD-4212A-600 AD-4212A-1000Mass of the special weighing pan AD-4212B series balance AD-4212B-101/102AD-4212B-201 AD-4212B-301Installing the Display Unit Installing in a panelSecure the weighing unit from above Attachment ProcedureAttaching the Mounting Fixtures Same for all the models External DimensionsDisplay unit Weighing unitWeighing unit with the mounting fixtures attached AD-1683 DC static eliminator OptionsAD-8121B Printer AD-1684 Electrostatic field meterOP-08 Ethernet interface OP-20 Metal leveling footIndex TERMS/INDEXTerms Cp fnc BepCl adj Cp HHOff G5iPnt RngTrc 5pd5t-b Memo

AD-4212A-100/200/600/1000, AD-4212A/B, AD-4212B-101/102/201/301 specifications

The A&D AD-4212 series, including models AD-4212B-101, AD-4212B-102, AD-4212B-201, AD-4212B-301, AD-4212A/B, and AD-4212A-100/200/600/1000, represents a significant advancement in precision weighing technology. A&D Company, a leader in the field of measurement and weighing solutions, has equipped these models with various features that cater to diverse industrial needs.

One of the standout characteristics of the AD-4212 series is its high precision load cell technology. This technology enables accurate measurements with a resolution that can reach up to 0.01 grams, making it suitable for industries where precision is paramount, such as pharmaceuticals and laboratories. Additionally, the series boasts an impressive overload protection feature, allowing it to handle weights significantly above its rated capacity without sustaining damage.

Durability and user-friendliness are also top priorities for the AD-4212 models. The devices are constructed using high-quality materials that ensure longevity, even in demanding environments. The intuitive user interface includes a large, easy-to-read LCD display, which enhances usability by allowing operators to view measurements and settings effortlessly.

Another essential feature of the AD-4212 series is its versatility in connectivity. These models support multiple communication protocols, including USB and RS-232, enabling seamless integration with computers and other devices for data output and printing. This connectivity capability facilitates streamlined operations in various settings, allowing for efficient data management and record-keeping.

User customization is also a significant aspect of these models. The AD-4212 series allows users to calibrate the devices according to their specific requirements, ensuring that they can tailor the performance to suit varied applications. Moreover, the models come with built-in functions for tare, hold, counting, and statistical calculations, making them extremely flexible for different weighing scenarios.

Energy efficiency is another noteworthy consideration in the design of the AD-4212 series. These models often feature automatic shut-off functions that help conserve energy, extending battery life and reducing operating costs. The combination of these technologies and characteristics makes the A&D AD-4212 series an exemplary choice for professionals seeking reliable and accurate weighing solutions across various industries. Overall, the AD-4212 models exemplify A&D's commitment to quality, precision, and user satisfaction.