A&D AD-4212A/B, AD-4212B-101/102/201/301, AD-4212A-100/200/600/1000 Introduction, Features

Page 6

1. INTRODUCTION

This manual describes how the AD-4212A/B series balance works and how to get the most out of it in terms of performance.

Read this manual thoroughly before using the balance and keep it at hand for future reference.

1-1 Features

Separate Weighing Unit and Display (standard connection cable length 2 m), suitable for building into a production line system. The weighing unit is compact, with a width of 80 mm.

High Resolution and High Response Speed

Model

Weighing capacity

Minimum weighing value

Stabilization time *1

AD-4212A-100

110 g

0.1 mg

1.1 to 1.3 seconds

AD-4212A-200

210 g

 

0.8 to 1.0 second

AD-4212A-600

610 g

1 mg

0.9 to 1.1 seconds

AD-4212A-1000

1100 g

 

 

 

AD-4212B-101

110 g / 31 g

0.1 mg / 0.01 mg

2.5 / 4.0 seconds *2

AD-4212B-102

110 g

0.01 mg

4.0 seconds *3

AD-4212B-201

210 g

0.1 mg

2.5 seconds

AD-4212B-301

310 g

 

 

*1 With FAST selected under good environment

*2 The AD-4212B-101 is equipped with a smart range function. When the minimum weighing value is set to 0.01 mg and the weight value exceeds 31 g, the minimum weighing value will switch to 0.1 mg automatically. Even under this circumstance, pressing the RE-ZERO key tares the value and weighing with the minimum weighing value of 0.01 mg is available up to 31 g.

*3 2.5 seconds when the minimum weighing value is 0.1 mg.

Standard RS-232C Serial Interface / Standard Comparator Contact Output (*4 )

Using the RS-232C serial interface, weighing data can be output to external devices and the balance can be controlled by external devices.

Using comparator contact output, the weight value is compared to the preset upper/lower limit

values and the results are displayed as HI, OK or LO. The buzzer is also available in response to the results.

The RE-ZERO operation is possible using a signal from an external contact input, which allows easy system construction. (This function is only available when the external contact input is installed on the standard interface or OP-01.)

*4 AD-4212A series balance: 3-level output.

AD-4212B series balance: 3-level or 5-level output, switched by the function table setting.

Data Memory Function, storing weighing data, calibration data, unit mass in the counting mode or upper/lower limit values. Once stored, selection of the upper or lower limit value is easy.

Dust-protected and Protected Against Splashing Water (Complying with IP54)

4

Image 6
Contents 212 B 1WMPD4001448CPage Contents ID Number and GLP Report TERMS/INDEX Features IntroductionCompliance with EMC Directives ComplianceCompliance with FCC Rules Windows is a registered trademark of Microsoft CorporationUnpacking the Balance UnpackingRear of the display unit Accessories AC adapter ID labelPlace the breeze break on the weighing pan so Installing the BalanceHow to install the breeze break That it fits over the dust guardHow to disconnect the cable from the weighing unit Rear of the weighing unitPrecautions Before UseWhen Building into a System Lighter heavier than the true weight. This Power Supply During UseAfter Use Processing indicator Display Symbols and KEY OperationDisplay symbols Stabilization indicatorWeighing Units UnitsProgrammable-unit Minimum Capacity Capacity Minimum DisplayChanging the Unit Basic Operation Gram Mode WeighingSmart Range Function Precision range/standard range value01 mg 0.1 mg Standard range Cond Changing the Weighing SpeedOperation Sensitive valueCalibration test CalibrationCalibration DisplayCalibration From previous Key until CCout Usable weights is shown on page 21, pressCalibration Test Return to CCFrom previous Permit or Inhibit Function Switch and InitializationSwitches For details, refer to 20. Extended FunctionsInitializing the Balance Be sure to calibrate the balance after initializationDisplay and Keys Function TableStructure and Sequence of the Function Table ExampleDetails of the Function Table Cpout Cp-t Output SettingData output mode Only the AD-4212B seriesInterval time Auto print polarityData memory Time/Date outputID number setting TimeoutAK, Error code Baud rateStability band width 5t-b Description of the Class Environment, DisplayCondition Cond Hold function Hold Animal weighing mode, AD-4212A onlyDisplay refresh rate 5pd Capacity indicator g5iZero tracking trc Decimal point pntStream mode Description of the Item Data output modeKey mode Tare at start p-trInterval memory mode Key mode BKey mode C Description of the Item Data formatMT format 5if type DP Dump print format 5if typeKF format 5if type NU numerical format 5if typeData number dout d-no Description of the Data Format Added to the Weighing DataID number Dout 5-id Date dout 5-td 2 orData Format Examples Positive errorNegative error Space 20hSetting the time with part of the digits blinking Clock and Calendar FunctionConfirming the time Set the date using the following keys Confirming the dateQuitting the operation Comparator Function Three-level comparison resultsFive-level comparison results Setting the upper/lower limit values Indicates a space 20hWhen three-level comparison is selected When five-level comparison is selectedConfirming the upper/lower limit values Adding the comparison results AD-4212A only Setting the ID Number ID Number and GLP ReportDisplay character set Calibration report When the setting is infoGLP Report Set the following parameters to output the reportCalibration test report using an external weight Title block and end block Weighing dataEnd block Counting Mode PC Selecting the counting modeStoring a sample unit mass Counting mode using the Acai function Counting operationSelecting the percent mode Storing the 100% reference massReading the percentage Releasing Clr Balance displays End Returns to the weighing modeData Memory Key until SClr noKey is pressed while the displayed value is Memory for Weighing DataStoring the weighing data Stable, the balance stores the weighing dataSetting the function table Press the CAL key to return to the weighing modeRecalling the memory data Transmitting all memory data at one time Deleting all memory data at one timeTransmitting the memory data Memory for Calibration and Calibration Test DataStoring the calibration and calibration test data Deleting the memory dataRecalling the unit mass Memory for Unit Mass in the Counting ModeKey To cancel the operation and go to step Key To increase the unit mass number by oneMemory for Upper/lower limit values Inputting the upper/lower limit values 3-level comparison Switching the upper/lower limit values 3-level comparison Confirming the coefficient Setting the coefficientUsing the function Selecting the programmable-unitSub 25 pin numbers Sub 25 pin assignments RS-232CExternal contact input Use a shieldedCable Use a shielded cableAD-8121B settings Mode PrtWhen multiple lines are to be printed, set the parameter to Connection to Peripheral EquipmentRsCom Using Windows Communication Tools WinCTConnection to a Computer RsKeyUsing the WinCT software, the balance can do the following Commands to query weighing data CommandsCommand List Commands to control the balanceAcknowledge Code and Error Codes Control Using CTS and RTS Settings Related to RS-232CConnector Pin Nos. and Specifications CablePin assignments and I/O logic OP-01 installation procedure Timing chartOn, T off 100 m sec or longer Extended Functions AD-4212A only Page Description of Averaging range and Averaging time Averaging range f1-b and averaging time f1-tCheck the balance performance using the self-check function MaintenanceTroubleshooting Checking the Balance Performance and EnvironmentOperating environment Weighing methodSample and container Error Codes Memory type error Unit mass errorClock battery error EC, E00 Communications errorAsking For Repair Specifications Power receptacle type Power consumption Calibration weight providedDisplay Dimensions 237 W × 150 D × 155 H mm Mass Counting Minimum unit mass ModeUsing the pan support Designing a Special Weighing PANPan support can be removed Using the pan boss Shock absorber specificationsPan boss can not be removed Mass of the special weighing pan AD-4212A series balance AD-4212A-100AD-4212A-200 AD-4212A-600 AD-4212A-1000Mass of the special weighing pan AD-4212B series balance AD-4212B-101/102AD-4212B-201 AD-4212B-301Installing the Display Unit Installing in a panelAttachment Procedure Attaching the Mounting FixturesSecure the weighing unit from above Same for all the models External DimensionsDisplay unit Weighing unitWeighing unit with the mounting fixtures attached AD-1683 DC static eliminator OptionsAD-8121B Printer AD-1684 Electrostatic field meterOP-08 Ethernet interface OP-20 Metal leveling footTERMS/INDEX TermsIndex Cp fnc BepCl adj Cp HHOff G5iPnt Rng5pd 5t-bTrc Memo

AD-4212A-100/200/600/1000, AD-4212A/B, AD-4212B-101/102/201/301 specifications

The A&D AD-4212 series, including models AD-4212B-101, AD-4212B-102, AD-4212B-201, AD-4212B-301, AD-4212A/B, and AD-4212A-100/200/600/1000, represents a significant advancement in precision weighing technology. A&D Company, a leader in the field of measurement and weighing solutions, has equipped these models with various features that cater to diverse industrial needs.

One of the standout characteristics of the AD-4212 series is its high precision load cell technology. This technology enables accurate measurements with a resolution that can reach up to 0.01 grams, making it suitable for industries where precision is paramount, such as pharmaceuticals and laboratories. Additionally, the series boasts an impressive overload protection feature, allowing it to handle weights significantly above its rated capacity without sustaining damage.

Durability and user-friendliness are also top priorities for the AD-4212 models. The devices are constructed using high-quality materials that ensure longevity, even in demanding environments. The intuitive user interface includes a large, easy-to-read LCD display, which enhances usability by allowing operators to view measurements and settings effortlessly.

Another essential feature of the AD-4212 series is its versatility in connectivity. These models support multiple communication protocols, including USB and RS-232, enabling seamless integration with computers and other devices for data output and printing. This connectivity capability facilitates streamlined operations in various settings, allowing for efficient data management and record-keeping.

User customization is also a significant aspect of these models. The AD-4212 series allows users to calibrate the devices according to their specific requirements, ensuring that they can tailor the performance to suit varied applications. Moreover, the models come with built-in functions for tare, hold, counting, and statistical calculations, making them extremely flexible for different weighing scenarios.

Energy efficiency is another noteworthy consideration in the design of the AD-4212 series. These models often feature automatic shut-off functions that help conserve energy, extending battery life and reducing operating costs. The combination of these technologies and characteristics makes the A&D AD-4212 series an exemplary choice for professionals seeking reliable and accurate weighing solutions across various industries. Overall, the AD-4212 models exemplify A&D's commitment to quality, precision, and user satisfaction.