How to use the on-screen menus
Four kinds of
Menu display
[MAIN MENU] |
|
1MARKER | 4 |
VIDEO CONFIG | 4 |
SYSTEM CONFIG | 4 |
OSD CONFIG | 4 |
GPI | 4 |
INPUT SELECT | 4 |
CONTROL | 4 |
MENUEXIT XWSEL ENTERENTER
This display appears when the MENU/EXIT button is pressed. If no further action is taken for the next 120 seconds, the display will be automatically cleared.
The position where the display appears on the screen can be changed using the marker setting.
For details on the menu, refer to “MAIN MENU” (page 15).
Status display
1SDI1 1080/60I
CRCC
2DC150V.60%
3
1Channel and signal format
The channel which has been
Similarly, “UNSUPPORTED SIGNAL” will also appear if signals not selected as the FORMAT item setting on the INPUT SELECT screen of the main menu are input even when those signals are supported.
For details on the signals supported and format displays, refer to page 12.
The status display information is displayed under the following conditions while the menu display is not on the screen.
≥When the input signals have been switched
≥When the input channel has been changed
≥When no signals are supplied
The display location and display time can be changed using the menu settings. When images are adjusted using the image controls while the status display information is on the screen, the display is cleared, and the settings adjusted by the controls are displayed instead.
2Warning display
This appears when an error has occurred or when a special mode is being used.
CRCC | This indicates a CRCC error, and it appears |
| when the SDI signals contain an error. |
FILM | This appears when the film mode (FILM) has |
| been selected as the GAMMA SELECT item |
| setting on the VIDEO CONFIG screen of the |
| main menu. |
| This appears when REMOTE has been |
| selected as the CONTROL item setting on the |
| CONTROL screen of the main unit. The |
| monitor controls will no longer function at this |
| time. |
3Battery voltage display
This indicates the voltage level of the battery. If an Anton Bauer digital battery is being used, its remaining level is indicated as a number of “∫” blocks and as a percentage along with the voltage value.
11