Care and Replacement
Replacing the lamp unit
Replacing
1.Turn off the MAIN POWER switch according to the procedure “Switching the projector on/off” on page 19, and then disconnect the mains plug from the mains socket and check that the area around the lamp unit has cooled down.
2.Use a Phillips screwdriver to turn the lamp unit cover fixing screws at the bottom of the projector, and then remove the lamp unit cover.
3.Use a Phillips screw driver to loosen the two lamp unit fixing screws until the screws turn freely. Then hold the handle of the lamp unit and gently pull it out from the projector.
4.Insert the new lamp unit while making sure that the direction of insertion is correct, and then use a Phillips screwdriver to securely tighten the lamp unit fixing screw.
5.Install the lamp unit cover, and then use a Phillips screwdriver to securely tighten the lamp unit cover fixing screws.
Lamp unit cover fixing screws
Lamp unit cover Lamp unit fixing screws
Press | Press |
here | here |
| Handle |
NOTE:
Be sure to install the lamp unit and the lamp unit cover securely. If they are not securely installed, it may cause the protection circuit to operate so that the power cannot be turned on.
Grip the handle when you remove the lamp unit. Some parts of the lamp unit are sharpened and may cause injury.
Resetting the LAMP RUNTIME
If the lamp usage time has passed 2 000 hours (when LAMP POWER has been set to NORMAL), the projector will switch to standby mode after approximately 10 minutes of operation. The resetting procedure should thus be completed within 10 minutes.
1.Insert the mains plug into the mains socket and then press the MAIN POWER switch.
2.Press the POWER button so that a picture is projected onto the screen.
3.Press the MENU button to display the menu screen, and then press the F or G button to select the OPTION menu.
4.Press the ENTER button, and then press the F or G button to select LAMP RUNTIME.
5.Press and hold the ENTER button for approximately
3 seconds. The confirmation screen, “LAMP RUNTIME RESET.” is displayed and select OK.
6.Turn off the power.
This will reset the cumulative usage time for the lamp unit to zero.
|
|
|
|
|
| INPUT GUIDE | DETAILED |
|
|
|
|
|
|
|
|
|
|
|
|
| OSD DESIGN | TYPE1 |
|
|
|
|
|
|
|
| OSD POSITION |
|
|
|
| CENTRE |
|
| |
|
|
|
|
|
| BACK COLOUR |
|
|
|
| BLUE |
|
| |
|
|
|
|
|
| STARTUP LOGO |
|
|
|
| ON |
|
| |
|
|
|
|
|
|
|
|
|
|
| AUTO SEARCH | ON |
|
|
|
|
|
|
|
| HDMI SIGNAL LEVEL |
|
|
|
| NORMAL |
|
| |
|
|
|
|
|
|
|
|
|
|
| INSTALLATION | FRONT/DESK |
|
|
|
|
|
|
|
| SLEEP |
|
|
|
| OFF |
|
| |
|
|
|
|
|
| ALTITUDE |
|
|
|
| LOW |
|
| |
|
|
|
|
|
| LAMP POWER |
|
|
|
| NORMAL |
|
| |
|
|
|
|
|
| LAMP RUNTIME | 1820H |
| |
| TEST PATTERN |
|
|
|
|
|
|
|
|
Maintenance