3 Wizard pages | Configuration process |
|
|
Step 2 System Information Setup page
zThe Unit Name appears on the button bar of the Web UI, near the corporate logo on the
Change the default name as desired.
zUnited States (US) and Canada (CA) are the two choices for the Country field in the current models.
The country selection defines some of the telephone standards that the BSGX4e uses.
Step 3 Date and Time Setup page
Most network equipment use a date and time signal in their internal processing, logging, and messaging functions. Your choices are:
zSNTP Enable
Simple Network Time Protocol refers to a network server that sends a date and time signal to the BSGX4e.
Choose yes if your service provider offers an SNTP server.
Choose no to set date and time manually.
z
z
z
SNTP IP/FQDN
If using an SNTP server, enter the IP address (ex. 123.156.7.89) or the FQDN (ex. some.domain.com).
GMT Offset
If using an SNTP server, enter the difference (offset) in hours from your location to Greenwich Mean Time (SNTP servers use GMT). For example, the East Coast of the U.S. is
Date and Time
If using manual settings, enter the current date and time here. All fields are numeric. The Hour field accepts
22 |