[Connections and Settings in Torque Control Mode]
Parameters, which are set up automatically
The following parameters are tuned automatically.
Parameter No. | Name |
11 | 1st speed loop gain |
12 | 1st speed loop integration time constant |
13 | 1st speed detection filter |
14 | 1st torque filter time constant |
19 | 2nd speed loop gain |
1A | 2nd speed loop integration time constant |
1B | 2nd speed detection filter |
1C | 2nd torque filter time constant |
20 | Inertia ratio |
The following parameters are also set up to the following fixed values automatically.
Parameter No. | Name | Set value |
27 | Disturbance torque observer filter selection | 0 |
30 | 2nd gain action | 1 |
3A | Torque control switching mode | 0 |
Caution
[1]Immediately after the first servo ON at startup or when Pr22 (machine stiffness at
1)Write the parameter of normal operation into the EEPROM.
2)Decrease the Pr22 (Machine stiffness at
3)Once set up Pr21
[2]After abnormal noise or oscillation, Pr20 (inertial ratio) may be changed to an extreme value. In such a case, also take the above measures.
[3]Among results of
Torque Control Mode
Connections and Settings in
143