Panasonic MINAS A3 Series Undervoltage, Error response, At main power-off, Dynamic breke, Action

Page 23

[Connections and Settings in Torque Control Mode]

 

 

 

 

 

 

 

 

Default setting is shown by [ ]

Parameter

Parameter Name

Setting

Unit

 

 

Function/Description

 

 

No.

range

 

 

 

 

 

 

 

 

 

 

 

 

 

65

Undervoltage

0 – 1

The parameter sets whether to enable the “protection against main power

 

error response

 

 

source under-voltage” function when you shut down the main power of

 

at main power-off

 

 

main and control power supplies.

 

 

 

 

 

 

 

 

Setting value

Main Power Source Under-voltage Protection Action

 

 

 

 

 

 

 

In this case, if you shut off the main power during Servo ON, it

 

 

 

 

 

 

0

will be SERVO-OFF without a trip. Then, when the main pow-

 

 

 

 

 

 

 

er supply turns ON again, it will be recovered to Servo ON.

 

 

 

 

 

 

 

Shutting off main power during Servo ON will activate ab-

 

 

 

 

 

 

[1]

normal main power supply under-voltage (alarm code

 

 

 

 

 

 

 

No.13) and cause a trip.

 

 

 

 

 

 

Refer to the timing chart “At Power ON” of Preparations volume on page 40.

 

 

 

 

 

 

 

 

 

 

66

Dynamic breke

0 – 1

The parameter sets driving conditions at decelerated operation after over-

 

inhibition at

 

 

travel input inhibit (CCWL: connector CN X5 9-pin or CWL: connector CN

 

overtravel limit

 

 

X5 8-pin) has been activated and enabled.

 

 

 

 

 

 

 

Setting value

Driving Conditions from Deceleration to Stop

 

 

 

 

 

 

[0]

The motor decelerates and stops as the dynamic brake (DB) is

 

 

 

 

 

 

operated. The motor will be in free condition after it stops.

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Free running, the motor decelerates and stops. The motor

 

 

 

 

 

 

will be in free condition after it stops.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

67

Error response

0 – 7

The parameter sets:

 

 

 

 

at main power-off

 

 

(1) Driving conditions during deceleration and after stopping; and

 

 

 

 

(2) Processing to clear content of the deviation counter

 

 

 

 

after the main power source is shut off.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting

Driving Conditions

Content of Deviation

 

 

 

 

 

 

value

During Deceleration

 

After Stopped

Counter

 

 

 

 

 

 

[0]

DB

 

DB

Clear

 

 

 

 

 

 

1

Free Run

 

DB

Clear

 

 

 

 

 

 

2

DB

 

Free

Clear

 

 

 

 

 

 

3

Free Run

 

Free

Clear

 

 

 

 

 

 

4

DB

 

DB

Retention

 

 

 

 

 

 

5

Free Run

 

DB

Retention

 

 

 

 

 

 

6

DB

 

Free

Retention

 

 

 

 

 

 

7

Free Run

 

Free

Retention

 

 

 

 

 

DB: Activation of dynamic brake

 

 

 

 

 

 

 

 

68

Error response

0 – 3

The parameter sets driving conditions during deceleration or following

 

action

 

 

stop, after any of protective functions of the driver has been activated and

 

 

 

 

alarm has been generated.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting

Driving Conditions

Content of Deviation

 

 

 

 

 

 

value

During Deceleration

 

After Stopped

Counter

 

 

 

 

 

 

[0]

DB

 

DB

Clear

 

 

 

 

 

 

1

Free Run

 

DB

Clear

 

 

 

 

 

 

2

DB

 

Free

Clear

 

 

 

 

 

 

3

Free Run

 

Free

Clear

 

 

 

 

 

(DB: Activation of dynamic brake)

 

 

 

 

 

 

 

See also “When Abnormality (Alarm) Occurs (Serve ON Command State)”

 

 

 

 

of the timing chart, Preparations volume on page 41.

 

 

 

 

 

 

 

 

 

 

69

Sequence at

0 – 7

• The parameter sets:

 

 

 

 

Servo-OFF

[0]

 

 

1) Driving conditions during deceleration or after stop

 

 

 

 

 

2) Processing to clear the deviation counter

 

 

 

 

 

 

 

following Servo off (SRV-ON signal: CN X5 29-pin turns On ‡ Off).

 

 

 

 

• A relationship between setting of Pr69 and driving conditions/deviation

 

 

 

 

 

counter processing conditions is similar to that of Pr67 (Sequence at

 

 

 

 

 

Main Power Off).

 

 

 

 

 

 

 

• See also “Serve On/Off Operation When the Motor Stops” of the timing

 

 

 

 

 

chart of Preparations volume on page 42.

 

 

 

 

 

 

 

 

 

 

 

 

 

Torque Control Mode

Connections and Settings in

153

Image 23
Contents CN X5 Connector Connections and Settings Torque Control ModeTorque control block diagram Circuits Available for Torque control mode CN X5 ConnectorConnections and Settings in Torque Control Mode CN X5 ConnectorInput Circuit Interface CircuitOutput Circuit Connections and Settings in Torque Control ModeInput Signals Common and their Functions Input signal common assignment to CN X5 connector pinsCLR INHZerospd GainInput Signals Speed Control and their Functions Coin + Output Signals Others and their FunctionsZSP TLCOperation with CN X5 Connected Trial run at Torque Control ModeWiring Diagram Input Signals StatusMemo Application range Real time auto gain tuningHow to use OutlineName Set value Parameters, which are set up automaticallyName Parameters for Function Selection Parameter SettingCCWL/CWL TLC output IM SignalsSet up IM selection1st speed GainIntegration time ConstantParameters for real time auto gain tuning 2nd notch Parameter Name Setting Unit Function/DescriptionDisturbance Torque observer Set value Cutoff Frequency Filter selectionParameters for Position Control Parameters for Switching to 2nd GainsParameters for Speed Control Parameters for various sequences Parameters for Torque ControlSetting Driving Conditions Error responseAt main power-off Main Power Source Under-voltage Protection ActionMotor standstill Delay atResister set up Main power-off