Panasonic MINAS A3 Series manual Interface Circuit, Input Circuit

Page 4

CN X5 Connector

Interface Circuit

Input Circuit

SI SI Connecting to sequence input signals

Connect to a contact of switch and relay, or a transistor of an open collector output.

Use a switch or relay for micro current so that insufficient contact can be avoided.

Lower limit of the power supply (12 to 24V) should not be less than 11.4V in order to secure the appropriate level of primary current of the photo coupler.

12–24V

7

COM+4.7k

 

 

Servo-ON or

 

 

other input

 

Relay

 

12–24V

7

COM+4.7k

 

 

Servo-ON or

 

 

other input

AI AI Analogue Command Input

There are three analogue command inputs of SPR/RTQR (14 pins), CCWTL (16 pins) and CWTL (18 pins).

The maximum permissible input voltage is ±10V. For the input impedance of these inputs, see the right figure.

If you make a simplified circuit comprising a variable re- sistor (VR) and resistor (R), refer to the right figure.

When the variable range of each input is -10V to +10V, the VR should be a B type resistor of 2k(min.1/2W). The R should be 200(min.1/2W).

The A/D converters for these inputs should have the fol- lowing resolution.

 

 

SPR/TRQR 14

20k

 

+12V

 

 

 

-

ADC

R

 

 

 

 

 

+

1

 

 

 

 

VR

15

GND

 

 

 

 

CCWTL 16

10k

-

 

 

-12V

+

 

 

 

 

 

 

R

17

GND

10k

ADC

 

 

 

 

 

2

 

 

CWTL 18

10k

-

 

 

 

+

 

 

 

 

 

 

 

 

 

 

10k

 

1) ADC1

(SPR and TRQR)

: 16 bits (including one bit for sign)

2) ADC2

(CCWTL and CWTL)

: 10 bits (including one bit for sign)

134

Image 4
Contents Connections and Settings Torque Control Mode CN X5 ConnectorTorque control block diagram CN X5 Connector Connections and Settings in Torque Control ModeCN X5 Connector Circuits Available for Torque control modeInterface Circuit Input CircuitConnections and Settings in Torque Control Mode Output CircuitInput signal common assignment to CN X5 connector pins Input Signals Common and their FunctionsINH ZerospdGain CLRInput Signals Speed Control and their Functions Output Signals Others and their Functions ZSPTLC Coin +Trial run at Torque Control Mode Wiring DiagramInput Signals Status Operation with CN X5 ConnectedMemo Real time auto gain tuning How to useOutline Application rangeName Parameters, which are set up automaticallyName Set value Parameter Setting Parameters for Function SelectionCCWL/CWL IM Signals Set upIM selection TLC outputGain Integration timeConstant 1st speedParameters for real time auto gain tuning Parameter Name Setting Unit Function/Description DisturbanceTorque observer Set value Cutoff Frequency Filter selection 2nd notchParameters for Switching to 2nd Gains Parameters for Position ControlParameters for Speed Control Parameters for Torque Control Parameters for various sequencesError response At main power-offMain Power Source Under-voltage Protection Action Setting Driving ConditionsDelay at Resister set upMain power-off Motor standstill