Trial run at Torque Control Mode
Operation with CN X5 Connected
1)Connect CN X5.
2)Connect the control signal
3)Turn the main power (driver) ON.
4)Check the defaults of the parameters.
5)Connect between
6)Apply an appropriate DC voltage between Torque command input TRQR (CN X5 pin 14) and GND (CN X5 pin 15) and verify the motor rotating direction (CW/CCW) and then reverse the voltage polarity and then verify reversed motor rotation. Also check the speed set by Pr56.
7)To change torque Pr5C, direction Pr5D and speed limit Pr56 in response to the command voltage, modify the following parameter.
Pr56: 4th speed
Pr5C: torque command input gain
Pr5D: torque command input inversion
Wiring Diagram
DC
12V – 24V
DC 10V
7
COM+
29SRV-ON
26ZEROSPD
41 | COM– |
|
14SPR/TRQR
15GND
ZEROSPD switch Close: Run Open: Stop
One way operation
For multi direction (CW and CCW) operation, use a bipolar power source.
PrNo. | Parameter description | Value | |
Pr02 | Control mode | 2 | |
Pr04 | Overtravel input inhibit | 1 | |
Pr06 | ZEROSPD input selection | 0 | |
Pr56 | 4th internal speed | Set as | |
Pr5C | Torque command input gain | ||
required | |||
Pr5D | Torque command input inversion | ||
|
• Use the controller to send command pulses.
Input Signals Status
No. | Input signal | Monitor | |
display | |||
|
| ||
0 | + A | ||
2 | CW overtravel inhibit | – | |
3 | CCW overtravel inhibit | – | |
5 | Speed zero clamp | – |