MGE UPS Systems 3000 RT 3U XL, EXB RT 3U Access to measurements and personalisation data

Page 16

4. Access to measurements and personalisation data

4.1 Display menus arrangement

Status and Alarms

Status and Alarms

Measurements

UPS input measurements

UPS output measurements

Battery measurements

Personalisation

Local personalisation

Output personalisation

ON/OFF personalisation

Battery personnalisation

4.2 Access to measurements

Press the scroll button (25) to access any status conditions and alarms, then the measurements for voltage, current, frequency, power output and battery backup time.

4.3 Personalisation using the control panel

 

25

ESC

26

Press the scroll button (25) several times until the personalisation menu is reached.

Press the Enter button (26) to access the different possibilities.

Finally, confirm the selection by pressing the Enter button (26) again.

Local personalisation

Function

Factory setting

Other available settings

 

 

 

Language

English

French, Spanish, German, Italian, Dutch

 

 

 

Audio alarm

Enabled

Disabled

 

 

 

34007776EN/AB - Page 16

Image 16
Contents Pulsar M 34007776EN/AB Introduction Environmental protectionSubstances PackingPictograms Contents Dimensions H x W x D in mm Weights in kgPresentation Standard positionsPulsar M EXB optional battery module Rear panelsControl panel Pulsar M 2200Installation Unpacking and contents checkInstallation in tower position Installation in rack position Communication ports Installation of the communication cards optionalConnection of RS232 or USB communication port optional Connections with a HotSwap MBP module optional FlexPDU moduleUPS connection without a FlexPDU or HotSwap MBP module HotSwap MBP-module operationUPS start-up with the HotSwap MBP module HotSwap MBP-module testOperation Operation on battery powerStart-up and normal operation Return of AC power Using the UPS remote control functionsEnd of battery backup time Remote control connection and testROO RPO Access to measurements and personalisation data Access to measurementsPersonalisation using the control panel Display menus arrangementPersonalisation using external software Battery personalisationOutput personalisation ON/OFF personalisationTroubleshooting MaintenanceIndication Diagnostic Correction Battery-module replacement Troubleshooting a UPS equipped with the HotSwap MBP moduleSafety recommendations Battery-module removalMaintenance on a UPS equipped with the HotSwap MBP module Mounting the new battery moduleMaintenance Return to normal operationTraining centre Hz training centreMGE UPS Systems FranceTechnical specifications AppendicesGlossary 34007776EN/AB