MGE UPS Systems user manual GES-801LR GES-102LR GES-152LR GES-202LR GES-302LR

Page 21

Always “On” UPS Systems Inc.

 

OUTPUT SHORT

 

 

YES

 

 

 

 

ABNORMAL VOLTAGE

 

 

YES

 

 

 

PROTECTION

MODEM OR NETWORK

SINGLE LINE (2 wire RJ11) / NETWORK (UTP, RJ45) COMPATIBLE JACKS

I/O NOISE PROTECTION

 

COMMON & NORMAL MODE NOISE SUPPRESSION

 

 

 

 

 

I/O SPIKE & TRANSIENT

 

 

YES

 

 

 

 

PROTECTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INTERFACE

COMMUNICATION

 

RS 232 / DRY CONTACT (OPTIONAL SNMP OR AS400)

 

LED DISPLAY

NORMAL / BACKUP / LOW BATTERY / FAULT / CHECK BATTERY / BUCK / BOOST

 

AUDIBLE ALARMS

 

ON BATTERY, LOW BATTERY, OVERLOAD, FAULT

 

ENVIRONMENT

OPERATING TEMPERATURE

 

0 - 40°C (32 - 104°F)

 

 

HUMIDITY

 

0 - 95% (NON-CONDENSING)

 

 

AUDIBLE NOISE

 

< 40 dBA AT 1 METER FROM UNIT

 

SAFETY APPROVAL

SAFETY

 

cUL,

UL1778, CSA C22.2

 

EMI / RFI

 

 

FCC CLASS B

 

 

 

 

SURGE / TRANSIENT

 

IEEE C62.41 CAT.A

 

 

 

UPS WxDxH mm (in.)

140x436x210 (5.5x17.2x8.3)

170x450x226 (6.7x17.7x8.9)

PHYSICAL DATA

EXTERNAL BATTERY BANK (if

 

INTERNAL BATTERIES

 

 

170x450x226

applicable)

 

 

 

(6.7x17.7x8.9)

 

 

 

 

 

 

WEIGHT in kg (lbs)

14.5 (32)

15 (33)

25 (55.1)

 

30 (66.1)

46 (101.4)

 

 

(including battery bank)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODEL NO.

GES-801LR

GES-102LR

GES-152LR

 

GES-202LR

GES-302LR

RACK-MOUNT MODELS

UPC Order Code

825433 22105

825433 22201

825433 22301

 

825433 22401

825433 22501

WxDxH mm (in.)

483x381x89 (19x15x3.5) [2U]

 

483x381x133

483x381x178

 

(19x15x5.25) [3U]

(19x15x7) [4U]

 

 

 

 

 

 

WEIGHT in kg (lbs)

18 (35.3)

20 (44)

26.1 (57.5)

 

28.4 (62.6)

46.4 (102.3)

21

Image 21
Contents Uninterruptible Power Supply Always On UPS Systems Inc Always On UPS Systems Inc Battery Replacement Troubleshooting Storage Introduction 36VDC Safety InstructionsFront Panel PresentationTELEPHONE/MODEM/ETHERNET Surge Protection Rear PanelSite Wiring Fault Indicators RED LED Installation Check the Site Wiring Fault Indicator Connecting the Telephone/Modem/Ethernet LinesOperation Audible Alarm Software Options UPSilon 2000 SoftwareInterface Kits Computer Interface Port Open Collector Dry Contact CommunicationRS-232 Communication Remove watches, rings, etc Use tools with insulated handles Battery ReplacementTroubleshooting Problems Possible causesSolution Storage Storage ConditionsExtended Storage Black RED Battery Bank InstallationSpecification SpecificationsGES-801LR GES-102LR GES-152LR GES-202LR GES-302LR Additional Purchases or Upgrades QA / Warranty QuestionsSoftware Questions