MGE UPS Systems Galaxy PW user manual Inverse video, Past events, Battery test

Page 29

User’s Manual

inverse video:

When this function is selected, the text and background colours are reversed (white text on black or black text on white).

past events:

See section "logging and time-stamping".

battery test:

the screen opposite is displayed when a battery test is requested. It indicates the battery charge status and the remaining service life. A manual or automatic test may be requested,

the screen opposite is displayed during a battery test, whether manual or automat- ic,

the screen opposite is displayed follow- ing a positive, manual battery test,

the screen opposite is displayed follow- ing a negative, manual battery test,

the screen opposite is displayed follow- ing a positive, automatic battery test. It indicates the time since the last test and provides access to test settings,

the screen opposite is displayed follow- ing a negative, automatic battery test. It indicates the time since the last test and provides access to test settings,

the screen opposite is displayed when the user requests access to the automatic test settings. It is possible to modify the interval between two automatic tests,

the screen opposite is displayed when the battery test cannot be completed.

CHARGE LEVEL

= -- %

REMAINING SERVICE LIFE

= -- MONTH

MANUAL TEST press key

AUTO TEST

press key

 

 

TESTING BATTERY

U BATTERY =

--- V

 

 

BATTERY TEST RESULT OK

BATTERY TEST RESULT NOT OK

TIME SINCE LAST TEST

WEEK -- DAY -- HOUR --

LAST BATTERY TEST RESULT OK

NEW PARAMETERS YES = NO =

TIME SINCE LAST TEST

WEEK -- DAY -- HOUR --

LAST BATTERY TEST RESULT NOT OK

NEW PARAMETERS YES = NO =

SELECT TIME OF NEXT TEST WITH KEYS ▼ ▼ CHANGE UNITS WITH

WEEK -- DAY -- HOUR -- confirm with key

TEST INTERRUPTED

CHECK PRESENCE OF THE BATTERY

CHECK ALARMS

Control-panel Display

21

Image 29
Contents Galaxy PW Page Galaxy PW User’s Manual Galaxy PW 100 to 225 kVA Important Safety Instructions This page intentionally left blank Service and Factory Repair Call 1 800 438 WarrantyGalaxy PW User’s Manual Galaxy PW TM 100 to 225 kVA User’s manualThis page intentionally left blank Contents Galaxy Pwtm 100 to 225 kVA How to use this manualIntroduction General characteristics of Galaxy PW UPSSystem description Schematic diagram of the Galaxy PW systemIsolation and protection devices Different types of Galaxy PW systemsSingle-UPS unit Parallel UPS system External bypass for parallel UPSs and the hot-swap optionBattery time Operation in on-line modeNormal operation Operation with the normal AC source downBattery charge cycle User’s Manual Operation with the normal AC source restoredInverter shutdown or overload Single-UPS unit on-line modeParallel UPSs with redundancy Parallel UPSs without redun- dancyOperation with an engine generator set Example of an installation with an engine generator setOutput voltage quality and continuity Steady state voltage regulationUPS cabinet Battery cabinetGalaxy PW cabinets Indications Control panelGeneral Inverter on button Start-up of a module Start-upSystem start-up Shutdown of the inverter ShutdownControl-panel display Display of alarmsGeneral organization Display of messagesGalaxy Pwtm 100 to 225 kVA List of primary messages Load Protected ON-LINE ModeLoad on Mains User’s Manual List of secondary messagesBattery Charging BAT. = XXX a U BAT. = XXX Current measurements Measurement systemVoltage measurements Set date and time Battery measurementsSelections and settings Past events Battery testInverse video Maintenance bypass AlarmsEnvironment information Signal receptionSignal transmission Utilization via the Galaxy PW display Logging and time-stampingPresentation of event time-stamping by Galaxy PW Example Consulting statisticsNb of backups 1 min this is Elapsed backup time min this isMin nb of backups 3 min this is Total time with Tbatt 25 C h thisBattery Utilization via TeleserviceMaintenance configuration MaintenanceSingle-UPS unit UPS isolationGalaxy PW External bypass Isolate all UPSsGalaxy PW Functional check Battery maintenanceVisual check Options Maintenance bypassGalvanic isolation and voltage matching transformers Electrical supervisionThis page intentionally left blank Scenic Avenue Costa Mesa, CA Reorder formPage Page Scenic Avenue, Costa Mesa, California 92626 714 557

Galaxy PW specifications

The MGE UPS Systems Galaxy PW is a high-performance uninterruptible power supply designed to provide reliable power protection for critical systems in various environments, including data centers, industrial settings, and commercial facilities. Known for its advanced features and innovative technologies, the Galaxy PW is engineered to ensure seamless operation, even in the event of power disturbances.

One of the standout features of the Galaxy PW is its modular design, allowing for easy scalability and flexibility. This design enables users to customize the power capacity according to their specific needs, accommodating future growth without requiring a complete system overhaul. The modular architecture consists of interchangeable power modules that can be easily added or replaced, ensuring minimal downtime and optimized performance.

The Galaxy PW uses cutting-edge double-conversion technology, which provides a high level of power quality and reliability. This technology ensures that any fluctuations in input power do not affect the output, delivering clean and stable electricity to connected equipment. This is particularly essential for sensitive electronics that require a consistent power supply to function correctly.

Another significant characteristic of the Galaxy PW is its energy efficiency. The UPS is designed to operate at high efficiency levels, often exceeding 96%. This not only helps in reducing the overall energy consumption but also lowers operational costs and reduces the carbon footprint of the facility. The Eco-Mode feature allows the UPS to deliver power with minimal energy loss during normal operating conditions.

The Galaxy PW is equipped with advanced communication and management features, including an intuitive graphical LCD display that provides real-time information on the system's status and performance metrics. Users can monitor input and output voltages, current load levels, and battery health at a glance. Additionally, the UPS supports various communication protocols and interfaces, facilitating integration with building management systems and remote monitoring tools.

Safety and reliability are also top priorities for the Galaxy PW. The system features robust battery management to extend the lifespan of the batteries while ensuring optimal performance. The UPS is designed with several protections, including overload, short-circuit, and thermal protection, to safeguard both the UPS and connected loads.

In summary, the MGE UPS Systems Galaxy PW integrates modularity, energy efficiency, advanced monitoring, and robust protection features to deliver unmatched reliability for critical power applications. Its innovative design and technologies make it an ideal choice for businesses seeking a reliable power protection solution.