•Replace the quick disconnects on the indicator lamp socket.
•Reconnect the utility wires and the stinger lug.
•Close the front door of the enclosure.
•Reinstall the FLM. Ensure the module is seated properly. Refer to Installing the FLM in this manual.
•Switch the FLM and the utility circuit breakers ON.
•Complete Performance Verification (refer to Initial Startup and Performance Verification in this manual).
•Replace the top door of the enclosure.
•Indicator Lamp Replacement
•Gently pry the lens off the indicator lamp using the tip of a screwdriver.
NOTE: Place a hand over the lens as it is loosened to ensure that the lens is not lost during the procedure.
•Remove the spent lamp and replace it with a new one.
•Snap the lens back into place.
•Euro Block Replacement
•Switch the utility circuit breaker OFF.
•Remove the doors to the enclosure.
•Remove the FLM.
•Disconnect (and tag), the wiring harness and utility wires from the Euro block.
•Remove the screws that secure the Euro block in the enclosure, and lift out the Euro block.
•Insert the new Euro block and secure it in the enclosure.
•Reconnect the wiring harness to the Euro block.
•Reinstall the FLM.
•Replace the doors on the enclosure.
•Switch the utility circuit breaker ON.
•Complete Performance Verification (refer to Initial Startup and Performance Verification in this manual).
11