American Power Conversion VS 100, VS 50 user manual Table of Contents

Page 2

 

 

Table of Contents

 

1

Introduction

6

 

1.1.

GENERAL INFORMATION

6

2

Installation

9

 

2.1.

UNPACKING EQUIPMENT

9

 

2.2.

MECHANICAL INSTALLATION

9

 

Room / Location

9

 

Mounting

9

 

Ventilation

9

 

2.3. AC POWER CONNECTIONS

10

 

AC Connections

10

 

AC Power Cord Sets

11

 

2.4.

BATTERY CONNECTIONS

12

 

Planning the Battery installation

12

 

Connecting the Cables

12

 

Battery Temperature Probe Installation

13

 

2.5. COUNTER ELECTRO-MOTIVEFORCE (CEMF) CELL CONNECTIONS

13

 

2.6. DC SYSTEM GROUNDING

14

 

2.7.

LOAD PROTECTION INSTALLATION

15

 

Circuit Breaker Installation

15

 

GMT Fuse Installation

15

 

2.8.

LOAD CONNECTIONS

15

 

Cable Size Considerations

15

 

Circuit Breaker Protected Load Connections (30 or 60 A)

16

 

GMT Fuse-protected Load Connections

16

 

2.9. MONITORING AND RELAY OUTPUT CONNECTIONS

17

 

Front Panel DB9 Connection

17

 

RJ45 Ethernet Connector

17

 

Major, Minor and Relay 1 Output Connections

17

 

Output Relay 2-6 Connections

18

 

External Alarm Input Connections

19

 

2.10.

RECTIFIER MODULE INSTALLATION

20

 

2.11.

CONTROLLER MODULE INSTALLATION

20

3

Commissioning

21

 

3.1.

PRE-COMMISSIONINGINSPECTION

21

 

Environment

21

 

Electrical Installation

21

 

Battery Visual and Safety Inspection

21

 

3.2.

COMMISSIONING

22

 

Initial Set-up

22

 

AC Power Up

22

 

DC Power Up:

22

 

Rectifier Test:

23

 

Battery Power Up

23

 

LVD Test

23

 

Circuit Breaker/ Fuse Test:

23

 

User Inputs

23

 

Output Relay 1:

24

 

Battery Temperature Compensation

24

 

3.3.

FINAL INSPECTION:

24

4

Technical Description

25

 

4.1.

RECTIFIER MANAGEMENT

25

 

AC Input Power

25

 

DC Output Power

25

 

Rectifier alarms reporting

25

 

4.2.

SYSTEM MANAGEMENT

25

 

System Voltage Monitor and Control

25

Magnum VS –48 Vdc User Manual

Page ii

Image 2
Contents Magnum VS Vdc Power Systems Table of Contents Programming Output Relays Table of Figures Page Introduction General InformationAccessories DescriptionPower Distribution Backplane ControlUnpacking Equipment InstallationMechanical Installation AC Power Connections AC ConnectionsAC Power Cord Sets Connecting the Cables Battery ConnectionsPlanning the Battery installation Recommended toBattery Temperature Probe Installation Counter Electro-Motive Force Cemf Cell ConnectionsDC System Grounding 1 Cemf Connection LocationsGMT Fuse Installation Load Protection InstallationCircuit Breaker Installation Load ConnectionsCircuit Breaker Protected Load Connections 30 or 60 a GMT Fuse-protected Load ConnectionsFront Panel DB9 Connection RJ45 Ethernet ConnectorMonitoring and Relay Output Connections Major, Minor and Relay 1 Output ConnectionsOutput Relay 2-6 Connections 1 Interface ConnectionsExternal Alarm Input Connections 2 Output Relay ConnectionsRectifier Module Installation Controller Module InstallationCommissioning Electrical InstallationBattery Visual and Safety Inspection Pre-Commissioning InspectionCommissioning AC Power UpDC Power Up Initial Set-upLVD Test Battery Power UpRectifier Test Circuit Breaker/ Fuse TestOutput Relay Battery Temperature CompensationFinal Inspection System Management Technical DescriptionRectifier Management System Current Monitor System Status and Alarm ReportingLoad Management Circuit BreakersGMT Fuses Battery ManagementBattery Charging Battery Low Voltage Disconnect Battery ProtectionBattery Temperature Monitoring Counter Electro-Motive Force Module ConnectionsExternal Alarm Inputs User Input Controls and IndicatorsAlarm Outputs Output Relays Network Management Card Local & Remote MonitoringController Module Jumpers OperationDescription Controller Module 1 Controller Card Jumper LocationsOperation Using the RS-232 Comm Port Magnum VS ControllerOperation Using the 10/100 BaseT Ethernet Port Settings Default Settings in Bold00 mV Distribution/BreakersDistribution/Fuses Power Modules/RectifiersSystem/Date & Time Batteries ParametersInput SecondsDisable OutputSeconds, 0.00 seconds Output RelaySystem/Out-Rly/Alias System/Preferences LVD Operation Programming Output RelaysEquipment Preventive MaintenanceSystem Visual and Safety Inspection InspectionTest Battery Preventive Maintenance Procedure Battery Current TestBattery Temperature Test Final Inspection Alarm Summary System LT Alm System Temperature is below Minor Magnum VS 100 Power System SpecificationsMagnum VS 50 Power System AC InputDC Output Magnum VS Controller Mechanical EnvironmentalCompliance APC Worldwide Customer Support Warranty Claims Terms of WarrantyNon-transferable Warranty Exclusions

VS 50, VS 100 specifications

American Power Conversion (APC), a brand under Schneider Electric, is renowned for its uninterruptible power supplies (UPS) and provides a range of solutions for both commercial and personal use. Among their various product lines, the APC Smart-UPS 1000VA (VS 1000) and Smart-UPS 500VA (VS 500) stand out due to their features, technologies, and specifications tailored to different operational needs.

The APC Smart-UPS 1000VA is designed for advanced power protection, capable of supporting servers, network equipment, and more demanding applications. It features a pure sine wave output, which is critical for sensitive electronics, ensuring devices receive a stable and clean power source even during outages. The VS 1000 is equipped with an extensive battery backup, offering up to 9 minutes of runtime at full load.

A notable technology employed in the Smart-UPS 1000 is the Automatic Voltage Regulation (AVR), which maintains output voltage stability by adjusting boost and trim in situations of under or over voltage. The unit has an LCD interface, providing real-time data regarding load capacity, runtime, and battery health, enabling users to easily monitor and manage performance. Additionally, with its compact design, the VS 1000 can fit into various settings, maximizing space efficiency.

In contrast, the APC Smart-UPS 500VA targets smaller operations, offering a more compact solution for basic power protection needs. Like its larger counterpart, it also provides pure sine wave output, ensuring the safe operation of connected equipment. The VS 500 is designed for less intensive applications, making it suitable for desktop computers, network devices, and home office setups.

The 500VA model supports shorter runtimes, typically around 3 to 6 minutes under full load but is ideal for situations where downtime needs to be minimized. The Smart-UPS 500VA features similar Automatic Voltage Regulation technology, maintaining voltage stability under fluctuating conditions. However, it comes with a more straightforward LCD display, providing essential information on power status and battery levels without overwhelming the user.

In summary, the APC Smart-UPS 1000VA and 500VA cater to different user requirements, with the VS 1000 offering robust features for larger setups and the VS 500 serving as a versatile option for home or small office use. Both models integrate essential technologies such as pure sine wave output and AVR, showcasing APC’s commitment to high-quality power solutions. Whether for commercial or personal use, these units demonstrate APC's ability to provide reliable power protection tailored to diverse needs.