American Power Conversion VS 100, VS 50 user manual Table of Figures

Page 4

MAGNUM VS CONTROLLER

50

8.4.

MECHANICAL

51

TWF0500H54B Rectifier

51

Magnum VS 50 Power System

51

Magnum VS 100 Power System

51

8.5.

ENVIRONMENTAL

51

8.6.

COMPLIANCE

52

8.7.

COMPLIANCE

52

8.8.

COMPLIANCE

52

9 APC Worldwide Customer Support

53

10

Limited Product Warranty

54

TWO YEAR FACTORY WARRANTY

54

10.1

54

 

Table of Figures

 

FIGURE 1.1-1 MAGNUM VS 50 –48 VDC POWER PLANT

6

FIGURE 1.1-2 MAGNUM VS BLOCK DIAGRAM

8

FIGURE 2.3-1 MAGNUM VS 50 BACKPLANE

10

FIGURE 2.3-2 AC INPUT WIRING

10

FIGURE 2.4-1 BATTERY CABLE CONNECTION LOCATIONS

13

FIGURE 2.4-2 BATTERY TEMPERATURE PROBE INSTALLATION

13

FIGURE 2.5-1 CEMF CONNECTION LOCATIONS

14

FIGURE 2.7-1 GMT FUSE TEMPERATURE DE-RATING CHART

15

FIGURE 2.8-1 CONNECTIONS TO CIRCUIT BREAKERS

16

FIGURE 2.8-2 TOP SHELF GMT FUSE CONNECTIONS

16

FIGURE 2.8-3 BOTTOM SHELF GMT FUSE CONNECTIONS

17

FIGURE 2.9-1 INTERFACE CONNECTIONS

18

FIGURE 2.9-2 OUTPUT RELAY CONNECTIONS

19

FIGURE 2.9-3 EXTERNAL USER INPUT CONNECTIONS

19

FIGURE 5.2-1 CONTROLLER CARD JUMPER LOCATIONS

31

FIGURE 0-1 MAGNUM VS CONTROLLER

32

FIGURE 5.5-1 PARAMETER LOCATIONS, DESCRIPTIONS, AND SETTINGS

34

Entire contents copyright 2007 American Power Conversion. All rights reserved. Reproduction in whole or in part without permission is prohibited.

APC and the APC logo are trademarks of American Power Conversion Corporation. All other trademarks, product names, and corporate names are the property of their respective owners and are used for informational purposes only.

Magnum VS –48 Vdc User Manual

Page iv

Image 4
Contents Magnum VS Vdc Power Systems Table of Contents Programming Output Relays Table of Figures Page Introduction General InformationAccessories DescriptionPower Distribution Backplane ControlMechanical Installation InstallationUnpacking Equipment AC Power Connections AC ConnectionsAC Power Cord Sets Battery Connections Planning the Battery installationConnecting the Cables Recommended toBattery Temperature Probe Installation Counter Electro-Motive Force Cemf Cell ConnectionsDC System Grounding 1 Cemf Connection LocationsLoad Protection Installation Circuit Breaker InstallationGMT Fuse Installation Load ConnectionsCircuit Breaker Protected Load Connections 30 or 60 a GMT Fuse-protected Load ConnectionsRJ45 Ethernet Connector Monitoring and Relay Output ConnectionsFront Panel DB9 Connection Major, Minor and Relay 1 Output ConnectionsOutput Relay 2-6 Connections 1 Interface ConnectionsExternal Alarm Input Connections 2 Output Relay ConnectionsRectifier Module Installation Controller Module InstallationElectrical Installation Battery Visual and Safety InspectionCommissioning Pre-Commissioning InspectionAC Power Up DC Power UpCommissioning Initial Set-upBattery Power Up Rectifier TestLVD Test Circuit Breaker/ Fuse TestFinal Inspection Battery Temperature CompensationOutput Relay Rectifier Management Technical DescriptionSystem Management System Status and Alarm Reporting Load ManagementSystem Current Monitor Circuit BreakersBattery Charging Battery ManagementGMT Fuses Battery Protection Battery Temperature MonitoringBattery Low Voltage Disconnect Counter Electro-Motive Force Module ConnectionsControls and Indicators Alarm Outputs Output RelaysExternal Alarm Inputs User Input Network Management Card Local & Remote MonitoringDescription OperationController Module Jumpers Controller Module 1 Controller Card Jumper LocationsOperation Using the RS-232 Comm Port Magnum VS ControllerOperation Using the 10/100 BaseT Ethernet Port Settings Default Settings in Bold00 mV Distribution/BreakersPower Modules/Rectifiers System/Date & TimeDistribution/Fuses Batteries ParametersInput SecondsDisable OutputSystem/Out-Rly/Alias Output RelaySeconds, 0.00 seconds System/Preferences LVD Operation Programming Output RelaysPreventive Maintenance System Visual and Safety InspectionEquipment InspectionTest Battery Temperature Test Battery Current TestBattery Preventive Maintenance Procedure Final Inspection Alarm Summary System LT Alm System Temperature is below Minor Specifications Magnum VS 50 Power SystemMagnum VS 100 Power System AC InputDC Output Magnum VS Controller Mechanical EnvironmentalCompliance APC Worldwide Customer Support Non-transferable Warranty Exclusions Terms of WarrantyWarranty Claims