American Power Conversion VS 50, VS 100 user manual Operation Using the 10/100 BaseT Ethernet Port

Page 33

5.4.Operation Using the 10/100 BaseT Ethernet Port

The RJ-45 10/100 Base-T port is primarily intended for connection to an intranet for remote access to the DC power system. However with the use of a crossover cable or a hub, a direct PC to 10/100 Base-T local connection may also be made.

After the Management Card is configured and running on your network, you can use several different interfaces to access the Management Card: Web, Telnet, SNMP and FTP.

-The Web interface uses a web browser such as Microsoft ® Internet Explorer 5.0 (and higher) or Netscape ® 4.0.8 (and higher) to configure Management Card options and to view DC power system status, alarms and events.

-Telnet is used to access a Management Card’s Control Console and is the same user interface available via the local RS-232 serial port.

-SNMP access is available after you add the PowerNet MIB to a standard SNMP MIB browser.

-FTP access is used to download new firmware to a Management Card, or to access a copy of a Management Card’s event or data logs.

Complete documentation for the use of the management card accompanies the DC power system in the form of a Quick Start Guide and a CD. The CD contains electronic copies of User’s Manuals along with the necessary software utilities to support the management function. Some of the functions supported by the network card are not supported by this power system.

5.5.Operation using Network Management Card Web Browser Interface

The location, description, and factory programmed default value for each of the Magnum VS system parameters accessible via a Web browser is found in the table below. The table also shows all of the status and information screens with typical displays. The location of a parameter screen is shown in brackets, for example: [Power Modules/Rectifiers]. This table is organized alphabetically by parameter name.

Magnum VS –48 Vdc User Manual

Page 33

Image 33
Contents Magnum VS Vdc Power Systems Table of Contents Programming Output Relays Table of Figures Page General Information IntroductionDescription AccessoriesControl Power Distribution BackplaneInstallation Mechanical InstallationUnpacking Equipment AC Connections AC Power ConnectionsAC Power Cord Sets Planning the Battery installation Battery ConnectionsConnecting the Cables Recommended toCounter Electro-Motive Force Cemf Cell Connections Battery Temperature Probe Installation1 Cemf Connection Locations DC System GroundingCircuit Breaker Installation Load Protection InstallationGMT Fuse Installation Load ConnectionsGMT Fuse-protected Load Connections Circuit Breaker Protected Load Connections 30 or 60 aMonitoring and Relay Output Connections RJ45 Ethernet ConnectorFront Panel DB9 Connection Major, Minor and Relay 1 Output Connections1 Interface Connections Output Relay 2-6 Connections2 Output Relay Connections External Alarm Input ConnectionsController Module Installation Rectifier Module InstallationBattery Visual and Safety Inspection Electrical InstallationCommissioning Pre-Commissioning InspectionDC Power Up AC Power UpCommissioning Initial Set-upRectifier Test Battery Power UpLVD Test Circuit Breaker/ Fuse TestBattery Temperature Compensation Final InspectionOutput Relay Technical Description Rectifier ManagementSystem Management Load Management System Status and Alarm ReportingSystem Current Monitor Circuit BreakersBattery Management Battery ChargingGMT Fuses Battery Temperature Monitoring Battery ProtectionBattery Low Voltage Disconnect Counter Electro-Motive Force Module ConnectionsAlarm Outputs Output Relays Controls and IndicatorsExternal Alarm Inputs User Input Network Management Card Local & Remote MonitoringOperation DescriptionController Module Jumpers 1 Controller Card Jumper Locations Controller ModuleMagnum VS Controller Operation Using the RS-232 Comm PortOperation Using the 10/100 BaseT Ethernet Port Settings in Bold Settings DefaultDistribution/Breakers 00 mVSystem/Date & Time Power Modules/RectifiersDistribution/Fuses Batteries ParametersSeconds InputOutput DisableOutput Relay System/Out-Rly/AliasSeconds, 0.00 seconds System/Preferences Programming Output Relays LVD OperationSystem Visual and Safety Inspection Preventive MaintenanceEquipment InspectionTest Battery Current Test Battery Temperature TestBattery Preventive Maintenance Procedure Final Inspection Alarm Summary System LT Alm System Temperature is below Minor Magnum VS 50 Power System SpecificationsMagnum VS 100 Power System AC InputDC Output Magnum VS Controller Environmental MechanicalCompliance APC Worldwide Customer Support Terms of Warranty Non-transferable Warranty ExclusionsWarranty Claims

VS 50, VS 100 specifications

American Power Conversion (APC), a brand under Schneider Electric, is renowned for its uninterruptible power supplies (UPS) and provides a range of solutions for both commercial and personal use. Among their various product lines, the APC Smart-UPS 1000VA (VS 1000) and Smart-UPS 500VA (VS 500) stand out due to their features, technologies, and specifications tailored to different operational needs.

The APC Smart-UPS 1000VA is designed for advanced power protection, capable of supporting servers, network equipment, and more demanding applications. It features a pure sine wave output, which is critical for sensitive electronics, ensuring devices receive a stable and clean power source even during outages. The VS 1000 is equipped with an extensive battery backup, offering up to 9 minutes of runtime at full load.

A notable technology employed in the Smart-UPS 1000 is the Automatic Voltage Regulation (AVR), which maintains output voltage stability by adjusting boost and trim in situations of under or over voltage. The unit has an LCD interface, providing real-time data regarding load capacity, runtime, and battery health, enabling users to easily monitor and manage performance. Additionally, with its compact design, the VS 1000 can fit into various settings, maximizing space efficiency.

In contrast, the APC Smart-UPS 500VA targets smaller operations, offering a more compact solution for basic power protection needs. Like its larger counterpart, it also provides pure sine wave output, ensuring the safe operation of connected equipment. The VS 500 is designed for less intensive applications, making it suitable for desktop computers, network devices, and home office setups.

The 500VA model supports shorter runtimes, typically around 3 to 6 minutes under full load but is ideal for situations where downtime needs to be minimized. The Smart-UPS 500VA features similar Automatic Voltage Regulation technology, maintaining voltage stability under fluctuating conditions. However, it comes with a more straightforward LCD display, providing essential information on power status and battery levels without overwhelming the user.

In summary, the APC Smart-UPS 1000VA and 500VA cater to different user requirements, with the VS 1000 offering robust features for larger setups and the VS 500 serving as a versatile option for home or small office use. Both models integrate essential technologies such as pure sine wave output and AVR, showcasing APC’s commitment to high-quality power solutions. Whether for commercial or personal use, these units demonstrate APC's ability to provide reliable power protection tailored to diverse needs.