American Power Conversion 240-320kW 480V manual Operation, Keyboard

Page 18

Operation

3.0 Operation

The display unit will read parameters, alarms/messages and measured values. LED alarm incorporates audible alarm, indicating unusual operating situations. The keyboard is used to program and control parameters and to display alarm messages and measured values.

3.1Keyboard

Displays battery voltage

Displays input voltage

Displays battery current

Displays input current

Displays time

Exits a mode

Displays output voltage

Schrolls up through list

Displays output current

Schrolls down through list

Stores parameters/ enter parameter stack

Displays

output frequency

Silences the audible alarm

Accesses

Chooses

alarm stack

parameters

NOTICE!

By pressing and simultaneously you increase back light contrast. The pressing of

and simultaneously decreases the contrast.

 

990-4039

 

 

18

User Guide APC Silcon 240-320kW 480V UPS

Image 18
Contents APC Silcon 240-320kW 480V UPS User Guide Copyright 2000 APC Denmark ApSSafety Symbols used in this manual User Guide APC Silcon 240-320kW 480V UPSThank You Contents Introduction IntroductionDisplay Unit Stop/Start UPS and Operating the External Service Bypass Stop UPS for stand-byStart UPS from stand-by Acoustic alarm sounds Stop UPS for complete power downSwitching off the UPS Reset the acoustic alarm by pressingStart UPS from complete power down UPS Start-upClose the front doors Operating the External Service Bypass Switch single systems Service Bypass Switch APC Silcon System OFF Normal operation Load power 0% Bypassing the Parallel UPS System All UPSs Dual UtilityLamp indication on Bypass Panel Stop/Start UPS and Operating the External Service Bypass Press On the keyboard Following can be carried out on any UPSIsolating one UPS in a Parallel/Redundant System Stop/Start UPS and Operating the External Service Bypass Operation OperationKeyboard Display of Measured Values Batt. load Batt. tankUsing the Remote Display Economy ModeParameter Settings Parameter SettingsParameter Settings Parameter Setting CommentsSwitching to Bypass Operation Programming KeysProgramming Example Load power xx% Displaying the Alarm Stack Alarms and EventsAlarms and Events Displaying the Event StackPossible alarms Alarms Description ActionDisplay will show invalid UPS data Rectifying Alarm Messages Parallel Operation AlarmsCorrection of false alarm situations during service Battery Monitoring Test Maintenance & TestingMaintenance & Testing Battery Capacity TestUntil Warranty WarrantyAPC Silcon UPS Limited Factory Warranty APC Corporate How to Contact APCHow to Contact APC APC Denmark