American Power Conversion 5000I user manual Specifications

Page 18

Specifications

Acceptable input voltage

0 - 325 VAC

Output voltage

196 - 253 VAC

Input protection

Resettable circuit breaker

Frequency limits (on-line operation)

47 - 63 Hz

Transfer time

2 ms typical, 4 ms maximum

Maximum load, total

5000 VA/3750 W

On-battery output voltage

220, 225, 230, or 240 VAC

On-battery frequency

50 or 60 Hz, 0.1 Hz;

 

unless synchronized to utility during brownout

On-battery waveshape

Low-distortion sine wave

Overload protection (on-battery)

Overcurrent and short-circuit protected, latching shutdown on overload

Noise filter

Normal and common mode EMI/RFI suppression,

 

100 kHz to 10 MHz

Battery type

Spill proof, maintenance free, sealed lead-acid

Typical battery life

3 to 6 years, depending on number of discharge cycles

 

and ambient temperature

Typical recharge time

2 to 5 hours from total discharge

Operating temperature

0 to 40ΓC (+32 to +104ΓF)

Storage temperature

-15 to +45ΓC (+5 to +113ΓF)

Operating and storage relative humidity

0 to 95%, non-condensing

Operating elevation

0 to +3,000 m (0 to +10,000 ft.)

Storage elevation

0 to +15,000 m (0 to +50,000 ft.)

Electromagnetic Compatibility (EMC)

EN50091-2

Electromagnetic Interference (EMI)

EN55022 Class A

Electromagnetic Immunity

IEC 801-2, 801-3, 801-4, 801-5, 1000-2-2

 

EN60555-1, -2, -3, EN61000-4-1, EN61000-4-11

Audible noise in dBA at 1 m (3 ft.)

z55

Safety approvals

GS licensed by VDE to EN50091-1-1 and 60950

Rack Mount Units

RM Unit

Size (W x H x D)

43.2 x 19.6 x 62.2 cm

 

(17.0 x 8.7 x 24.5 in.)

Weight - net (shipping)

205 (235) lb.

 

93 (106.6) kg

Tower Units

Tower Unit

Size (W x H x D)

19.6 x 43.2 x 62.2 cm

 

(8.7 x 17.5 x 26.0 in.)

Weight - net (shipping)

200 (240) lb.

 

93 (106.6) kg

990-7032A, Revision 3 7/01

12

Image 18
Contents 990-7032A, Revision 3 7/01 990-7032A, Revision 3 7/01 Handling Safety Electrical SafetyReplacement and Recycling of Batteries Page Table of Contents Page Introduction ContentsHow to Unpack the UPS UnpackingInstalling Rack Mount Units InstallationPlacement Position the UPSInstall the Mounting Rails in the Rack Hardwire the Electrical Connection Load the UPS into the RackConnect Power to the UPS Install the BatteriesConnect Power and Equipment to the UPS Install PowerChute and AccessoriesInitial Startup Low Battery Warning Interval Operating Instructions Storage Replacing the Battery UPS battery life differs based on usage and environment User Configuration ItemsHow to Determine On-Battery Run Time Tower and 5U Rack Mount 5000 VA ModelsSpecifications Regulatory Agency Approvals Troubleshooting If the UPS requires service do not return it to the dealer ServiceLimited Warranty APC Contact InformationRacks Rack Type Hole Type Hardware Required Hardware IncludedAppendix B Transporting Your Smart-UPS