Page 22

Appendix A: Types of Racks and Mounting Hardware

This appendix describes the hardware required for the different types of racks and describes the type of racks that may be used in your industry. All APC Rack Mount units are shipped ready for 19-inch wide EIA/IEC rack cabinets. Refer to the instructions included with the rails when mounting the UPS.

Racks

There are different types of racks:

Equipment Rack - usually an open rack with threaded mounting holes or no threaded holes

APC Netshelter, IBM (Vero, others) - enclosed rack with square holes

Dell, Compaq (Rittal) - enclosed rack with square holes

HP Rack - enclosed rack with round holes

These racks differ in the methods required for mounting equipment. They may have threaded holes (hardware not included), round holes (require clip nut, shown below), or square holes (require cage nut, shown below).

• Telecomm Rack - open rack with two poles/four poles and threaded round holes (hardware not supplied by APC).

Notes:

Remove batteries to reduce UPS weight.

For larger, heavier units, installation should be performed by two people.

Check the type of rack you have against the hardware required for mounting in the table below.

Rack Type

Hole Type

Hardware Required

Hardware Included

Equipment Rack

Threaded or

See rack specifications if threaded.

N/A if threaded.

 

No Threads

If not threaded use APC hardware.

If not threaded use APC

 

 

 

hardware.

Netshelter/Compaq/IBM/Dell

Square

Cage nut, 10-32 screws

810-2008, 810-0002

HP

Round

Clip nut, 10-32 screws

810-2004, 810-0002

Telecomm

Threaded

See rack specifications

N/A

990-7032A, Revision 3 7/01

16

Image 22
Contents 990-7032A, Revision 3 7/01 990-7032A, Revision 3 7/01 Electrical Safety Handling SafetyReplacement and Recycling of Batteries Page Table of Contents Page Introduction ContentsHow to Unpack the UPS UnpackingInstalling Rack Mount Units InstallationPlacement Position the UPSInstall the Mounting Rails in the Rack Hardwire the Electrical Connection Load the UPS into the RackConnect Power to the UPS Install the BatteriesConnect Power and Equipment to the UPS Install PowerChute and AccessoriesInitial Startup Low Battery Warning Interval Operating Instructions Storage Replacing the Battery UPS battery life differs based on usage and environment User Configuration ItemsHow to Determine On-Battery Run Time Tower and 5U Rack Mount 5000 VA ModelsSpecifications Regulatory Agency Approvals Troubleshooting If the UPS requires service do not return it to the dealer ServiceLimited Warranty APC Contact InformationRacks Rack Type Hole Type Hardware Required Hardware IncludedAppendix B Transporting Your Smart-UPS