APC SMX1000 VA, SMX48RMBP2U Display Panel, Overview, Using the display interface, Standard menus

Page 7

Display Panel

Overview

Online LED

UPS Output On/Off button

On Battery LED

Site Wiring Fault LED

Replace Battery LED

Display screen

UP/DOWN arrow buttons

ENTER button

 ESCAPE button

Using the display interface

APC by Schneider Electric

su0343a

Use the UP/DOWN arrow buttons to scroll through the main menu options. Press ENTER to view the submenus under each main menu option. Press ESCAPE to exit a submenu and return to a main menu.

Standard menus

The Standard menus are the most commonly used menus for the UPS.

Menu

General Functions

 

 

 

View basic information about the UPS:

 

• Operating mode

 

• Switched Outlet status, On or Off

 

• Efficiency of the UPS

Status

• Information about the load

• Battery capacity

 

• Estimated runtime

 

• Input and output voltage and frequency

 

• Information about the last transfer to battery power

 

Self-test results

 

• SmartSlot Card information

 

 

 

Configure the settings for the UPS:

 

• Language

Configuration

• Local power quality: Good, Fair, Poor

• Choose Standard or Advanced menus

 

 

• UPS Test settings

 

• Reset to Factory Defaults

 

 

Test & Diags

Use the Test & Diags menu to have the UPS perform a self-test.

 

 

 

Display information about this unit:

 

• Unit model number

 

• Serial number

About

• Battery information

•Model number

 

 

•Installation date

 

•Suggested battery replacement date

 

•UPS firmware version

Smart-UPS X 750/1000/1500 VA 120/230 Vac Rack-Mount 2U

5

Image 7
Contents Smart-UPS X Uninterruptible Power Supply Page Safety and General Information Important Safety MessagesProduct Description 120 Vac Front Panel FeaturesRear Panel Features Product OverviewNetwork Management Card External Battery Pack SpecificationsInstallation Environmental SpecificationsOperation Basic ConnectorsConnect Equipment to the UPS Standard menus Using the display interfaceDisplay Panel OverviewControl Advanced menusLog General Settings ConfigurationUPS Settings Start up settingsControllable Outlet Groups 1500 VA 120/230 Vac Model specific controllable outlet groups750 VA 120 Vac 1000 VA 120/230 VacUsing the controllable outlet groups and UPS outlets On Battery Turn On DelayTurn Off Delay Reboot DurationNetwork Management Card Settings Normally open contacts Emergency Power OffNormally closed contacts Display interface LEDs flash sequentially TroubleshootingUPS does not provide expected backup time UPS is emits intermittent beepsUPS displays a site wiring fault message Replace Battery LED is illuminatedTransport the unit ServiceNon-transferable warranty Two Year Limited Factory WarrantyPage 990-3458B 04/2013 APC by Schneider Electric Worldwide Customer Support